Evidence map›Paper›PMID 42197731›Full record

ArticleSensors (Basel, Switzerland)2026

Low-Cost Portable Sensor Node for Gas and Chemical Leak Detection with Kalman-Filtering-Based UWB Localization.

Mohammed Faeik Ruzaij Al-Okby, Thomas Roddelkopf, Kerstin Thurow

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mohammed Faeik Ruzaij Al-OkbyCenter for Life Science Automation (Celisca), University of Rostock, 18119 Rostock, Germany.ORCID 0000-0001-8084-6361
Thomas RoddelkopfInstitute of Automation, University of Rostock, 18119 Rostock, Germany.ORCID 0000-0002-5115-9519
Kerstin ThurowCenter for Life Science Automation (Celisca), University of Rostock, 18119 Rostock, Germany.ORCID 0000-0002-3281-1065

Funding

European Research Council 856405
6 · The paper itself

Abstract

The work environment in automated laboratories and industrial sites exposes workers to the risks associated with chemical gas and vapor leaks caused by unforeseen incidents. Such leaks may result in severe health hazards as well as damage to equipment or infrastructure at the leak site. Therefore, the development of systems capable of early detection and highly accurate localization of chemical leaks is of high importance for occupational safety. In this work, a low-cost, portable sensor node based on the Internet of Things (IoT) is proposed for the detection and localization of gas and chemical leaks in indoor environments. The sensor node features a modular design that enables flexible integration and replacement of gas and environmental sensors depending on the target application. In addition, the system includes an ultra-wideband (UWB)-based positioning and tracking unit, allowing operation across multiple indoor zones. The main contribution of this work lies in the combined integration of (i) multi-sensor-based environmental event detection and prediction and (ii) high-precision location within a dynamic multi-zone tracking architecture. The system automatically selects the most relevant anchors in each zone and applies trilateration and least-squares estimation, enhanced by Kalman filtering techniques. In particular, an extended Kalman filter (EKF) and an unscented Kalman filter (UKF) are employed, with sensor fusion incorporating inertial measurement unit (IMU) data to mitigate the effects of on-line-of-sight (NLoS) conditions and signal degradation caused by obstacles. Experimental results demonstrate that both the EKF and UKF significantly reduce positioning errors and improve tracking stability compared to baseline methods under challenging indoor conditions. The UKF shows superior performance in highly nonlinear scenarios. A quantitative evaluation using manually surveyed reference points showed that the UKF achieved the best overall performance, with a mean error of 39.72 cm and an RMSE of 43.03 cm. These findings confirm the effectiveness of Kalman filter-based sensor fusion for reliable indoor positioning and highlight the suitability of the proposed system for real-time safety monitoring applications.

Indexed as

ambient monitoringenvironmental monitoringextended Kalman filter (EKF)gas sensorsharmful gaseshazardous gasesKalman filters (KF)sensor nodeunscented Kalman filter (UKF)volatile organic compounds (VOCs)

Identifiers

PMID42197731
PMCPMC13211003

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.