Electrical Resistance Activation of Embedded Fe-SMA Rebars in Pre-Cracked UHPFRC Beams: Internal Temperature Evolution and Calibrated Electro-Thermal Simulation.

Alireza Tabrizikahou, Jan Białasik, Karol Nowak, Krzysztof Lehmann, Grzegorz Trzmiel, Arkadiusz Dobrzycki

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alireza TabrizikahouInstitute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland.ORCID 0000-0002-3161-2224
Jan BiałasikInstitute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland.ORCID 0000-0003-0919-4115
Karol NowakInstitute of Electric Power Engineering, Poznan University of Technology, 60-965 Poznan, Poland.ORCID 0000-0002-0469-3217
Krzysztof LehmannInstitute of Building Engineering, Poznan University of Technology, Piotrowo 5, 60-965 Poznan, Poland.
Grzegorz TrzmielInstitute of Electrical Engineering and Electronics, Faculty of Control, Robotics and Electrical Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland.ORCID 0000-0002-3622-8889
Arkadiusz DobrzyckiInstitute of Electrical Engineering and Electronics, Faculty of Control, Robotics and Electrical Engineering, Poznan University of Technology, Piotrowo 3A, 60-965 Poznan, Poland.ORCID 0000-0001-5640-685X

Funding

National Science Centre 2023/49/N/ST8/03063Poznań University of Technology 0412/SBAD/0091
6 · The paper itself

Abstract

Iron-based shape memory alloy (Fe-SMA) rebars can generate internal prestress in cement-based members after restrained thermal activation; however, the temperature actually reached by embedded rebars in cracked UHPFRC is difficult to infer from exposed bar segments. This study investigates electrical resistance activation of 4% prestrained Fe-SMA rebars embedded in pre-cracked UHPFRC beams and clarifies the activation-control problem by combining thermocouple measurements with a calibrated two-dimensional electro-thermal simulator. Twelve beams (150 × 150 × 600 mm) containing either Dramix 3D or Dramix 4D hooked steel fibers were first loaded in three-point bending to a mid-span displacement of 4 mm. The 4D series reached a 9.47% higher average pre-cracking load, confirming that fiber geometry modified the cracked state before heating. During activation, the exposed rebar segment reached 200 °C after approximately 77 s, whereas the embedded working segment reached the same target only after approximately 213 s; at that moment, the exposed segment was already close to 350 °C. The calibrated simulator reproduced the target activation time with an error of approximately 3 s and visualized the localized heat transfer from Fe-SMA to UHPFRC. The results demonstrate that activation control based only on exposed-bar temperature may cause under-activation of the embedded reinforcement, and that direct internal temperature monitoring is required for reliable Fe-SMA activation in cracked UHPFRC members.

Indexed as

activation temperatureelectrical resistance activationelectro-thermal simulationFe-SMAfiber-reinforced high-performance concrete

Identifiers

PMID42195802
PMCPMC13208856

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.