Evidence map›Paper›PMID 42195688›Full record

ArticleMaterials (Basel, Switzerland)2026

The Failure of Voltage Divider Induced by Insulating Material Degradation Under Coupling Effect of High-Frequency Field and Temperature.

Xuan Li, Chuang Zhang, Zixi Liu, Jiajie Song, Huidong Tian, Qijia Xie, Zhengmao Zhang, Shengtao Li

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xuan LiEquipment Management Department of State Grid Corporation of China, Beijing 100032, China.
Chuang ZhangSchool of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Zixi LiuSchool of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Jiajie SongState Grid Economic and Technological Research Institute Co., Ltd., Beijing 102200, China.
Huidong TianState Grid Economic and Technological Research Institute Co., Ltd., Beijing 102200, China.
Qijia XieState Grid Hubei Electric Power Co., Ltd., Wuhan 430048, China.
Zhengmao ZhangState Grid Hubei Electric Power Co., Ltd., Wuhan 430048, China.
Shengtao LiSchool of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China.

Funding

Headquarters' Science and Technology Project of State Grid Corporation of China (Ascent Plan) 5100-202422368A-3-1-DG
6 · The paper itself

Abstract

This paper systematically investigates the failure characteristics and mechanisms of insulating materials in DC voltage dividers under combined high-frequency voltage and high-temperature conditions via simulations and experiments. The results showed that high-frequency harmonics severely degrade the insulation strength of polypropylene/paper/polypropylene (PPLP) at 10 kHz, in which the bulk breakdown strength of PPLP decreases by over 50%. Furthermore, the surface flashover voltage in oil is reduced by 17.7% under high-frequency voltage alone, and by as much as 51% when white flocculent substances are present in the oil. The dielectric properties of PPLP strongly depend on frequency and temperature, which aggravate the heat accumulation of the divider under high-frequency voltage. Furthermore, the multilayer structure of PPLP introduces deeper trap levels due to interfacial states, which reduce the breakdown strength and flashover voltage of PPLP. Electro-thermal coupling induces a rapid temperature rising to 98 °C at 25 kHz caused by dielectric loss, leading to oil turbidity and white precipitation, consistent with finite element simulations. Consequently, a failure mechanism is proposed as follows: prolonged electro-thermal stress causes chain scission in styrene-containing materials, releasing monomers that repolymerize into white polystyrene deposits. Their porous structure and dielectric mismatch distort the interfacial field, trigger partial discharge, and aggravate surface flashover.

Indexed as

dielectric lossfailure of dividerflashoverhigh-frequency harmonicspolypropylene/paper/polypropylene

Identifiers

PMID42195688
PMCPMC13208765

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.