Evidence map›Paper›PMID 42194264›Full record

ArticleBioengineering (Basel, Switzerland)2026

Effect of Alumina Airborne-Particle Abrasion Followed by Plasma Treatment on Bond Strength of Dental PEEK to MMA-Based Luting Systems.

Taro Mukaibo, Takafumi Watanabe, Ayako Miura, Kanna Saimoto, Misaki Matsuo, Hiromichi Ogusu, Chihiro Masaki, Hiroshi Ikeda

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Taro MukaiboDivision of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Kitakyushu 803-8580, Japan.ORCID 0000-0002-3650-9250
Takafumi WatanabeDivision of Occlusion and Maxillofacial Reconstruction, Kyushu Dental University, Kitakyushu 803-8580, Japan.ORCID 0009-0001-7319-2424
Ayako MiuraDivision of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Kitakyushu 803-8580, Japan.
Kanna SaimotoDivision of Biomaterials, Kyushu Dental University, Kitakyushu 803-8580, Japan.
Misaki MatsuoDivision of Biomaterials, Kyushu Dental University, Kitakyushu 803-8580, Japan.ORCID 0009-0002-5035-8708
Hiromichi OgusuDivision of Occlusion and Maxillofacial Reconstruction, Kyushu Dental University, Kitakyushu 803-8580, Japan.ORCID 0009-0001-3599-6974
Chihiro MasakiDivision of Oral Reconstruction and Rehabilitation, Kyushu Dental University, Kitakyushu 803-8580, Japan.
Hiroshi IkedaDivision of Biomaterials, Kyushu Dental University, Kitakyushu 803-8580, Japan.ORCID 0000-0002-7187-1722

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Poly (ether ether ketone) (PEEK) has attracted increasing attention for dental applications because of its favorable mechanical properties, physicochemical stability, and biocompatibility. However, its inherently poor bonding characteristics remain a major limitation in clinical practice. This study investigated the effect of sequential alumina airborne-particle abrasion (sandblasting) followed by plasma treatment on the bonding performance of methyl methacrylate (MMA)-based luting systems to dental CAD-CAM PEEK. PEEK specimens were prepared as plates and divided into four surface-treatment groups: untreated, airborne-particle abraded, plasma-treated, and airborne-particle abraded followed by plasma treatment. Surface characteristics were evaluated using SEM-EDX analysis and surface roughness measurements, and surface wettability was assessed by contact angle measurements using primers from two MMA-based luting systems (Beautylink [BL] and Super-Bond [SB]). Shear bond strength (SBS) between treated PEEK and each luting system was determined after 24 h of water storage (initial) and after 20,000 thermocycles (aged). Airborne-particle abrasion significantly increased surface roughness, whereas plasma treatment enhanced surface wettability without altering roughness. The combined treatment resulted in the highest surface roughness and the lowest contact angles and demonstrated superior or comparable SBS compared with the single treatments. After aging, the combined treatment significantly improved bonding durability. These findings indicate that airborne-particle abrasion followed by plasma treatment enhances the bonding performance and durability of MMA-based luting systems to PEEK.

Indexed as

bond strengthplasmapoly (ether ether ketone)resin cementsandblastsurface modification

Identifiers

PMID42194264
PMCPMC13203191

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.