Evidence map›Paper›PMID 42194253›Full record

ArticleBioengineering (Basel, Switzerland)2026

Osteoporotic Bone Quality Significantly Increases Proximal Stress Concentration: A Comparative Thermoelastic Stress Analysis with Normal Composite Femurs.

Ryunosuke Watanabe, Shota Yasunaga, Fumi Hirose, Koshiro Shimasaki, Tomohiro Yoshizawa, Yasuhiro Homma, Tomofumi Nishino, Hajime Mishima, Yoshihisa Harada

Abstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Ryunosuke WatanabeDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.ORCID 0000-0001-6675-5244
Shota YasunagaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.
Fumi HiroseDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.
Koshiro ShimasakiDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.ORCID 0000-0002-9495-837X
Tomohiro YoshizawaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.
Yasuhiro HommaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.
Tomofumi NishinoDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.ORCID 0000-0002-6755-4900
Hajime MishimaDepartment of Orthopaedic Surgery, Institute of Medicine, University of Tsukuba, Tsukuba 305-8575, Japan.
Yoshihisa HaradaCore Manufacturing Technology Research Institute, National Institute of Advanced Industrial Science and Technology, Tsukuba 305-8565, Japan.

Funding

Japan Society for the Promotion of Science 24K19563
6 · The paper itself

Abstract

Proximal femoral fractures associated with osteoporosis are an important clinical problem, yet how bone quality independently influences stress distribution remains insufficiently understood. This study aimed to quantitatively compare surface stress distribution between normal and osteoporotic proximal femoral models using thermoelastic stress analysis (TSA). Fourth-generation composite femurs with identical external geometries were subjected to cyclic compressive loading at a 9° adduction angle, with different maximum loads applied to avoid structural failure (normal: 1900 N; osteoporotic: 1000 N). TSA was performed using an infrared lock-in system to obtain surface stress maps, and stress values were evaluated across key proximal regions and along the medial and lateral cortices. The osteoporotic group showed higher maximum stress values in the medial neck (-37.79 vs. -11.52 MPa), lateral neck (24.70 vs. 8.75 MPa), and intertrochanteric crest (-17.98 vs. -6.05 MPa), corresponding to approximately 1.8-3.5-fold increases compared with the normal model values normalized to 1000 N. Mean stress values were also higher by approximately 1.9-2.4-fold across regions. These results suggest that reduced bone quality is associated with increased proximal stress concentration. They may also help guide implant and fixation strategies, including stem selection and fixation configuration, by identifying regions susceptible to stress concentration under different bone quality conditions.

Indexed as

biomechanicscomposite femurfemoral stress distributionosteoporosisthermoelastic stress analysis

Identifiers

PMID42194253
PMCPMC13203903

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.