ArticleAnimals : an open access journal from MDPI2026
Rotational Stability in a Feline Sacroiliac Luxation Model: Biomechanical Comparison of Cannulated Compression Headless Screws and Cortical Screws Applied in Positional or Lag Fashion.
Article in Animals : an open access journal from MDPI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of this study was to compare the rotational stability of cannulated compression headless screws (CCHSs) with cortical positional and lag screws in a simulated cadaveric feline sacroiliac luxation (SIL) model. Thirty-six cadavers of domestic short-haired cats were assigned to three groups. A unilateral SIL model was stabilized using either a single 2.5 mm CCHS, a 2.4 mm cortical positional screw (PS) or lag screw (LS), each engaging 60% of the sacral width. The pelves were mounted in a mechanical testing machine and loaded through the acetabulum to simulate ground reaction forces. Constant displacement was applied at 0.5 mm/s until maximal failure occurred. Yield load, ultimate load, stiffness, and failure modes were compared among the three groups. At the yield load, a statistical trend was observed among the groups, and pairwise comparison showed a significant difference between CCHS and PS. However, no significant differences were identified among the groups for yield load, ultimate load, or stiffness. All specimens failed due to screw loosening, and failure modes differed between CCHSs and cortical screws. Overall, CCHSs and cortical screws placed in a positional or lag fashion showed comparable rotational stability under the single load-to-failure conditions used in this feline SIL model. These findings question the biomechanical advantage of compression screws regarding rotational strength in unilateral feline SIL.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.