Evidence map›Paper›PMID 42193856›Full record

ArticleAnimals : an open access journal from MDPI2026

Rotational Stability in a Feline Sacroiliac Luxation Model: Biomechanical Comparison of Cannulated Compression Headless Screws and Cortical Screws Applied in Positional or Lag Fashion.

Jana Klement, Josef Wieser, Christoph Thorwächter, Yury Zablotski, Nina Dorothee Lorenz, Susanne Lauer, Matthias Kornmayer

Abstract read
In one paragraph

Article in Animals : an open access journal from MDPI, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jana KlementVeterinary Practice Dr. Zauscher, 85235 Odelzhausen, Germany.
Josef WieserDepartment of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, 81377 Munich, Germany.ORCID 0009-0007-9050-1296
Christoph ThorwächterDepartment of Orthopedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, 81377 Munich, Germany.ORCID 0000-0002-6298-6202
Yury ZablotskiLMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität, 80539 Munich, Germany.ORCID 0000-0001-6928-4089
Nina Dorothee LorenzNorthern Rivers Veterinary Specialists, Bangalow, NSW 2479, Australia.
Susanne LauerLMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität, 80539 Munich, Germany.ORCID 0000-0002-5425-7261
Matthias KornmayerLMU Small Animal Clinic, Centre for Clinical Veterinary Medicine, Ludwig-Maximilians-Universität, 80539 Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this study was to compare the rotational stability of cannulated compression headless screws (CCHSs) with cortical positional and lag screws in a simulated cadaveric feline sacroiliac luxation (SIL) model. Thirty-six cadavers of domestic short-haired cats were assigned to three groups. A unilateral SIL model was stabilized using either a single 2.5 mm CCHS, a 2.4 mm cortical positional screw (PS) or lag screw (LS), each engaging 60% of the sacral width. The pelves were mounted in a mechanical testing machine and loaded through the acetabulum to simulate ground reaction forces. Constant displacement was applied at 0.5 mm/s until maximal failure occurred. Yield load, ultimate load, stiffness, and failure modes were compared among the three groups. At the yield load, a statistical trend was observed among the groups, and pairwise comparison showed a significant difference between CCHS and PS. However, no significant differences were identified among the groups for yield load, ultimate load, or stiffness. All specimens failed due to screw loosening, and failure modes differed between CCHSs and cortical screws. Overall, CCHSs and cortical screws placed in a positional or lag fashion showed comparable rotational stability under the single load-to-failure conditions used in this feline SIL model. These findings question the biomechanical advantage of compression screws regarding rotational strength in unilateral feline SIL.

Indexed as

biomechanical studycatfelineheadless compression screwlag screwpositional screwrotational stabilitysacroiliac luxation

Identifiers

PMID42193856
PMCPMC13203331

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.