Evidence map›Paper›PMID 42192246›Full record

ArticleMedical physics2026

Noisy probing dose facilitated dose prediction for pencil beam scanning proton therapy: Physics enhances generalizability.

Lian Zhang, Jason M Holmes, Xiao Zhang, Zhengliang Liu, Hongying Feng, Mingzhu Li, Terence T Sio, Carlos E Vargas, Sameer R Keole, Kristin Stützer and 6 more

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Lian ZhangDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Jason M HolmesDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Xiao ZhangDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Zhengliang LiuSchool of Computing, University of Georgia, Athens, GA, USA.
Hongying FengDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Mingzhu LiDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Terence T SioDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Carlos E VargasDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Sameer R KeoleDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Kristin StützerOncoray - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.
Sheng LiSchool of Data Science, University of Virginia, Charlottesville, Virginia, USA.
Tianming LiuSchool of Computing, University of Georgia, Athens, GA, USA.
Jiajian ShenDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
William W WongDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Sujay A VoraDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.
Wei LiuDepartment of Radiation Oncology, Mayo Clinic, Phoenix, Arizona, USA.

Funding

Dose Linear Energy Transfer Volume Histogram and Dosimetric Seed Spot Analysis in Spot Scanning Proton TherapyR01CA280134 · NCI · MAYO CLINIC ARIZONA · PI Wei Liu · 2024 to 2026
$1.7M
Online Adaptive Proton TherapyR01EB293388 · NIBIB · MAYO CLINIC ARIZONA · PI Wei Liu · 2025 to 2026
$1.3M
Fred C. and Katherine B. Anderson Foundation Translational Cancer Research AwardNCI NIH HHS R01 CA280134NIBIB NIH HHS R01 EB293388NIH/NCI R01CA280134NIH/NIBIB R01EB293388the Eric & Wendy Schmidt Fund for AI Research & Innovationthe Kemper Marley Foundation
6 · The paper itself

Abstract

backgroundAccurate and efficient dose calculation is essential for online adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results for pencil beam scanning proton therapy (PBSPT) in recent years, but existing DL-based dose prediction methods still suffer from limited generalizability and an inability to effectively handle outlier clinical cases. This may lead to inaccurate dose delivery to targets or excessive irradiation to organs at risk (OARs), thereby compromising the safety and efficacy of online adaptive proton therapy. PURPOSE: To design a physics-aware and generalizable AI-based PBSPT dose prediction method that incorporates underlying physics to enhance generalizability, particularly in handling outlier clinical cases.

methodsThis study analyzed PBSPT plans of 103 prostate (93 for training and 10 for testing) and 78 lung cancer patients (68 for training and 10 for testing) from our institution, with each case comprising CT images and structure sets. Using the doses generated by our Monte Carlo-based dose engine as the reference standard, we compared three methods: the region of interest (ROI)-based method, the beam mask and sliding window method, and the proposed noisy probing dose method, which rapidly generates a low-statistics dose via uniformly weighted spots on an expanded spot-placement target volume without optimization. To evaluate the generalizability of these methods to rare treatment planning scenarios, 12 cases with uncommon beam angles or prescription doses were used to assess their performance, which was evaluated using dose-volume histogram (DVH) indices, 3D Gamma passing rates (3%/2 mm/10%), and Dice coefficients for dose agreement, while prediction times were measured to gauge model efficiency.

resultsThe proposed noisy probing dose method consistently outperformed the ROI-based and beam mask baselines across all evaluated metrics, with more accurate dose agreement and superior generalizability. For DVH indices, the noisy probing dose method achieved the smallest deviation in clinical target volume (CTV) dose coverage: in prostate cancer, CTV D98 deviation was reduced by 45% (from 0.53 ± 0.22 Gy [RBE] for ROI-based) and 29% (from 0.41 ± 0.28 Gy [RBE] for beam mask) to 0.29 ± 0.06 Gy [RBE]; in lung cancer, similar improvements were observed, with CTV D98 deviations reduced to 0.34 ± 0.12 Gy [RBE]. The 3D Gamma passing rates improved to 99.65% ± 1.15% for prostate targets and 97.04% ± 1.17% for lung targets. The dice coefficients of the 90% iso-dose lines were also the highest with the noisy probing dose method (prostate: 0.983 ± 0.005; lung: 0.967 ± 0.01). For the 12 outlier cases, the noisy probing dose method maintained superior generalizability, yielding higher 3D Gamma passing rates (prostate targets: 96.79% ± 0.83%, OARs: 94.29% ± 1.01%; lung targets: 93.38% ± 1.34%, OARs: 93.95% ± 1.32%), demonstrating robust generalizability to rare clinical scenarios. The dose predictions for all testing cases were completed within 0.3 seconds.

conclusionsA novel noisy probing dose method was proposed for PBSPT dose prediction in prostate and lung cancer patients. By embedding more proton-specific physics, this method demonstrated an improvement in the generalizability of dose prediction.

Indexed as

Deep LearningLungLung NeoplasmsOrgans at RiskProstateProstatic NeoplasmsRadiotherapy Planning, Computer-AssistedFemaleHumansMaleMonte Carlo MethodProton TherapyRadiotherapy DosageSignal-To-Noise Ratiodose predictiongeneralizabilitynoisy probingproton therapy

Identifiers

PMID42192246
PMCPMC13293102

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.