ArticleMagma (New York, N.Y.)2026
Optimization of fetal brain MRI at 0.55 T with slice-to-volume reconstruction.
Article in Magma (New York, N.Y.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectiveFetal brain MRI is extremely challenging due to motion and relies almost exclusively on 2D single-shot imaging with multi-stack acquisition. 3D slice-to-volume reconstruction (SVR) has been used to improve through-plane resolution and conspicuity and compensate for the fetal motion. Lower field strengths such as 0.55 T are emerging as an important tool for fetal evaluation due to improved safety and patient comfort, reduced cost, and potential for better access. This study aims to determine the impact of 0.55 T fetal brain MRI acquisition parameters on fetal brain SVR reconstruction performance and determine optimal settings. MATERIALS AND
methodsWe recruited nine healthy pregnant women (ten fetuses). Fetal brain imaging was performed at 0.55 T using T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence in three orthogonal orientations. We acquired scans for four echo time (TE) values (98,140,181, and 272 ms) with 12 stacks (4 in each major orientation, fetal-axial, fetal-sagittal, and fetal-coronal). SVR was performed for 2 to 12 stacks for four the TE values; the results were evaluated qualitatively and quantitatively by a pediatric radiologist.
resultsWith increasing TE, WM-GM contrast improves, and WM and GM SNR efficiency decreases, as expected. As the number of stacks increases, the SNR, structural similarity, and normalized error of SVR reconstruction monotonically improve, as expected. A TE of 140 ms, coupled with six stacks, provided radiologist preferred contrast to noise, with the shortest possible scan time.
conclusionSVR is applicable to fetal brain MRI at 0.55 T and benefits from a longer TE and larger number of stacks than is typically used at 1.5 T or 3 T.
Indexed as
Identifiers
42192054What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.