Evidence map›Paper›PMID 42191764›Full record

ArticleScientific reports2026

An ultra-sensitive multi-channel MEG system for the non-invasive single-trial detection of cortical population spikes.

Jim Barnes, Soudabeh Arsalani, Gunnar Waterstraat, Gabriel Curio, Lukasz Radzinski, Jens Haueisen, Rainer Körber

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jim BarnesPhysikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587, Berlin, Germany. Jim.Barnes@ptb.de.
Soudabeh ArsalaniPhysikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587, Berlin, Germany.
Gunnar WaterstraatNeurophysics Group, Department of Neurology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Hindenburgdamm 30, 12203, Berlin, Germany.
Gabriel CurioNeurophysics Group, Department of Neurology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Hindenburgdamm 30, 12203, Berlin, Germany.
Lukasz RadzinskiNeurophysics Group, Department of Neurology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, Hindenburgdamm 30, 12203, Berlin, Germany.
Jens HaueisenInstitute of Biomedical Engineering and Informatics, Faculty of Computer Science and Automation, Technische-Universität Ilmenau, 98693, Ilmenau, Germany.
Rainer KörberPhysikalisch-Technische Bundesanstalt (PTB), Abbestrasse 2-12, 10587, Berlin, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We describe the design and performance of a highly sensitive 12-channel magnetoencephalography (MEG) system to be operated in a magnetically shielded room. The aim of the recording system is to measure spatially resolved high frequency (450-850 Hz) somatosensory evoked responses (hfSERs), as elicited by electrostimulation of the median nerve, at a single-trial level. The system uses current sensing superconducting quantum interference devices (SQUIDs) operated in an ultra-low noise dewar. The sensor head consists of 9 multi-turn, hexagonal signal magnetometers, 2 single-turn, circular reference magnetometers and one circular axial gradiometer. Given limitations in the dewar's size, a balance was found between minimising the magnetic field noise and the spatial distribution of the individual MEG channels. Using SQUIDs currently made at the Physikalisch-Technische Bundesanstalt, the minimum white noise performance is expected to be [Formula: see text], with the achieved noise performance in the frequency band of interest of [Formula: see text]. Additionally, simulations of the neuronal magnetic field of the hfSERs predicted a peak-to-peak strength of 35 fT for our system, in accordance with previous recordings. We also present measures to increase the dynamic range of our MEG device and show in vivo measurement results which demonstrate spatially resolved detection of the hfSERs with amplitudes of [Formula: see text] at the single-trial level.

Indexed as

Evoked Potentials, SomatosensoryMagnetoencephalographyElectric StimulationHumansMedian NerveMagnetoencephalographySomatosensory evoked responsesSQUID current sensorUltra-low noise dewar

Identifiers

PMID42191764
PMCPMC13219391

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.