Evidence map›Paper›PMID 42189346›Full record

ArticleEJNMMI physics2026

Correcting fast irregular motion in PET: maximum-likelihood motion and activity (MLMA) reconstruction.

Rodrigo José Santo, Ethan Waterink, Cornelis A T van den Berg, Thomas Olausson, Alessandro Sbrizzi, Hugo W A M de Jong, Casper Beijst

Abstract read
In one paragraph

Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Rodrigo José SantoDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands. r.josesanto@umcutrecht.nl.ORCID http://orcid.org/0009-0006-6698-3718
Ethan WaterinkDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0009-0007-9577-0153
Cornelis A T van den BergDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-5565-6889
Thomas OlaussonDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0001-7063-1607
Alessandro SbrizziDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-3276-4542
Hugo W A M de JongDepartment of Radiology & Nuclear Medicine, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-3000-8316
Casper BeijstDepartment of Radiotherapy, Imaging & Oncology Division, UMC Utrecht, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-1672-3230

Funding

Nederlandse Organisatie voor Wetenschappelijk Onderzoek 19003
6 · The paper itself

Abstract

purposePositron emission tomography (PET) imaging naturally suffers from motion blur due to long acquisitions. As such, motion-compensation provides a promising solution to improve image quality. Traditional methods for motion-correction often involve a combination of gating and data-binning, assuming that motion is periodic, to accumulate sufficient counts per motion-state frame. Irregular motion can be estimated but it requires complex motion-capture systems or elaborate data-driven algorithms, which are difficult to configure (physical or model setup) and hampered by the high noise of short timeframes. We propose a new method that alternatingly estimates and corrects for motion at high temporal frequency in PET imaging: Maximum-Likelihood Motion and Activity (MLMA) reconstruction. MLMA estimates both the time-series of deformation vector fields and the motion-corrected activity image for the whole acquisition. Together, this allows to visualize anatomical structures moving in time.

methodsThe method exploits the high compressibility and spatial smoothness of motion through a cubic B-spline motion-model and through spatial regularization. MLMA was configured to 2 Hz resolution and applied on (A) the digital XCAT phantom, (B) acquisitions of a moving anthropomorphic torso phantom and (C) clinical patient data.

resultsThe results show that MLMA can accurately correct motion at high frequency (2 Hz), with subvoxel accuracy (up to 2.5 mm root-mean-square error (RMSE) on 4 mm isotropic voxels) and realistic breathing (amplitude range 14.7 mm and average period 4.5 s). This enables visually-noticeable improvements on image quality.

conclusionThe proposed MLMA reconstruction method resolves the motion encoded in very-short PET timeframes, irrespective of the very low counts and noise inherent to PET projection data.

Indexed as

Gateless motion-corrected PETHigh-frequency motion-corrected PETirregular non-rigid motion correctionMotion correction

Identifiers

PMID42189346
PMCPMC13433875

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked