Mechanical Fatigue of Titanium Dental Implants After Implantoplasty: An In Vitro Study Combined with Finite Element Simulations.
Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The increasing prevalence of peri-implantitis has led to a growing clinical use of implantoplasty, a procedure involving intraoral machining of the dental implant surface to remove biofilm. The absence of standardized clinical protocols may contribute to premature fatigue failure of dental implants. The present study aimed to evaluate the influence of machining depth on the cyclic mechanical behavior of dental implants. A total of 250 commercially pure grade 4 titanium dental implants were distributed into four groups according to machining depth: untreated (original), 0.2 mm, 0.4 mm, and 0.6 mm wall reduction. The implant system featured an internal connection with a thread height of 0.4 mm. Finite element analysis was performed for each machining depth to evaluate von Mises stress distribution and simulate fatigue behavior. The numerical models were validated through experimental fatigue testing using a servo-hydraulic MTS Bionix testing machine under ISO 14801:2016 conditions, showing a high correlation between simulated and experimental results (correlation coefficients > 0.9). The results indicated that maximum von Mises stresses were concentrated at the junction between the implant thread and the implant body. The fatigue limit of the untreated implants was approximately 351 N. Implants subjected to 0.4 mm machining exhibited a fatigue limit of 301 N, whereas lower fatigue limits were observed for 0.2 mm (255 N) and 0.6 mm (185 N) reductions. These findings suggest a significant mechanical effect of thread removal: 0.4 mm implantoplasty may provide improved fatigue performance compared to 0.2 mm, potentially due to reduced stress concentration at the thread-body junction. At high applied loads, fracture occurred in the coronal region of the implant, whereas at lower loads failure shifted to the implant-abutment connection. Although a good agreement between numerical and experimental results was observed, these findings should be interpreted with caution due to the in vitro testing conditions and the assumptions inherent to the finite element simulations. Therefore, while the results suggest that implantoplasty depth should not exceed the original thread height, further validation under clinically relevant conditions is required to confirm its impact on long-term mechanical reliability.