ArticleJournal of functional biomaterials2026
Mechanobiological Response of Peri-Implant Bone to Variations in Inter-Implant Distance: A Finite Element Analysis of Conometric Implants at Crestal and Subcrestal Positions.
Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Inter-implant distance (IID) is crucial for peri-implant bone preservation and long-term implant success. Traditionally, a minimum IID of 3 mm is recommended to limit marginal bone loss, although the biomechanical effect of smaller distances remains debated and may depend on multiple biological, prosthetic, and surgical factors. This study uses finite element analysis (FEA) to evaluate the effect of IID on stress distribution in peri-implant bones of D3 and D4 quality, considering crestal versus subcrestal implant placement, and interpreting results within Frost's mechanostat theory. Implants with an internal conometric connection were modeled within simulated D3 and D4 mandibular bone blocks. IID values of 3 mm, 1.5 mm, and 1 mm were analyzed under masticatory load. Von Mises stresses in cortical and trabecular bone were compared against biomechanical thresholds (2 MPa disuse and 20 MPa remodeling limit). Results: Cortical stress increased with decreasing IID, more pronounced in crestal placement. In D3 bone, maximum cortical stress rose from 7.2 MPa (3 mm IID) to 16.5 MPa (1 mm IID) under crestal placement, while remaining within the mechanostat-based thresholds adopted in the present stress-interpretation framework. In D4 bone, cortical stress approached 20 MPa at 1 mm IID under crestal placement, indicating a less favorable mechanical condition within the interpretive framework adopted. Subcrestal placement reduced cortical stresses in both bone qualities. Trabecular stress remained stable in D3 (~1.7-8 MPa) and increased moderately in D4 (~up to 13 MPa). Conclusions: Within the limitations of this preclinical finite element study, decreasing inter-implant distance was associated with increased cortical stress, while subcrestal placement was associated with lower cortical stress than crestal placement. These findings should be interpreted only as comparative computational results, and no direct clinical conclusion can be drawn regarding the acceptability of a 1 mm inter-implant distance.