Mechanobiological Response of Peri-Implant Bone to Variations in Inter-Implant Distance: A Finite Element Analysis of Conometric Implants at Crestal and Subcrestal Positions.

Mario Ceddia, Tea Romasco, Natalia Di Pietro, Luciano Lamberti, Bartolomeo Trentadue

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mario CeddiaDepartment of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.ORCID 0009-0002-2002-9938
Tea RomascoDepartment of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0002-4868-3838
Natalia Di PietroDepartment of Medical, Oral and Biotechnological Sciences, "G. D'Annunzio" University of Chieti-Pescara, 66100 Chieti, Italy.ORCID 0000-0001-9720-2116
Luciano LambertiDepartment of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.
Bartolomeo TrentadueDepartment of Mechanics, Mathematics and Management, Polytechnic University of Bari, 70125 Bari, Italy.ORCID 0000-0002-5759-0692

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Inter-implant distance (IID) is crucial for peri-implant bone preservation and long-term implant success. Traditionally, a minimum IID of 3 mm is recommended to limit marginal bone loss, although the biomechanical effect of smaller distances remains debated and may depend on multiple biological, prosthetic, and surgical factors. This study uses finite element analysis (FEA) to evaluate the effect of IID on stress distribution in peri-implant bones of D3 and D4 quality, considering crestal versus subcrestal implant placement, and interpreting results within Frost's mechanostat theory. Implants with an internal conometric connection were modeled within simulated D3 and D4 mandibular bone blocks. IID values of 3 mm, 1.5 mm, and 1 mm were analyzed under masticatory load. Von Mises stresses in cortical and trabecular bone were compared against biomechanical thresholds (2 MPa disuse and 20 MPa remodeling limit). Results: Cortical stress increased with decreasing IID, more pronounced in crestal placement. In D3 bone, maximum cortical stress rose from 7.2 MPa (3 mm IID) to 16.5 MPa (1 mm IID) under crestal placement, while remaining within the mechanostat-based thresholds adopted in the present stress-interpretation framework. In D4 bone, cortical stress approached 20 MPa at 1 mm IID under crestal placement, indicating a less favorable mechanical condition within the interpretive framework adopted. Subcrestal placement reduced cortical stresses in both bone qualities. Trabecular stress remained stable in D3 (~1.7-8 MPa) and increased moderately in D4 (~up to 13 MPa). Conclusions: Within the limitations of this preclinical finite element study, decreasing inter-implant distance was associated with increased cortical stress, while subcrestal placement was associated with lower cortical stress than crestal placement. These findings should be interpreted only as comparative computational results, and no direct clinical conclusion can be drawn regarding the acceptability of a 1 mm inter-implant distance.

Indexed as

bone lossFEAinter-implant distanceinternal connection

Identifiers

PMID42188375
PMCPMC13207950