Evidence map›Paper›PMID 42188236›Full record

ArticleJournal of imaging2026

A Cost-Effective and Rapidly Manufacturable Infrared-Visible High-Contrast Calibration Board Based on Structural Parametrization.

Yuandong Shao, Aleksandr S Vasilev

Abstract read
In one paragraph

Article in Journal of imaging, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Yuandong ShaoInstitute "Higher School of Engineering and Technology", ITMO University, Saint Petersburg 197101, Russia.ORCID 0009-0009-5877-1506
Aleksandr S VasilevInstitute "Higher School of Engineering and Technology", ITMO University, Saint Petersburg 197101, Russia.ORCID 0000-0002-2080-3252

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The infrared (IR)-visible light (VIS) dual-camera system provides complementary cues for image fusion, but issues such as geometric mismatch caused by different imaging methods, inconsistent resolution/field-of-view, and installation offsets often lead to ghosting and artifacts. This study aims to develop a fast-deployable and repeatable calibration workflow based on cost-effective calibration board. We designed an infrared-visible high-contrast checkerboard plate that can be generated through structural parameterization and efficiently manufactured using Python/OpenSCAD. We also established a corner-based registration pipeline that estimates global homography to align the visible-light images onto the infrared pixel grid for fusion and quantitative evaluation. Experiments conducted in a controlled indoor environment demonstrated stable sub-pixel performance within a range of 1.5-2.5 m, with an average re-projection error of 0.47-0.50 pixels per frame and a 95th percentile lower than 0.51 pixels. The corner position re-projection error test further confirmed stability near image boundaries, with a median value of 0.53-0.63 pixels and a 95th percentile of 0.54-0.64 pixels. Overall, the proposed target design and workflow can achieve practical infrared-visible calibration under typical deployment constraints and have repeatable accuracy, providing geometrically consistent input for subsequent fusion and dataset construction.

Indexed as

checkerboard calibrationcost-effective calibrationhomographyimage fusioninfrared–visible registration

Identifiers

PMID42188236
PMCPMC13207807

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.