Evidence map›Paper›PMID 42187468›Full record

ArticleBiosensors2026

Low-Effort Respiratory Function Estimation with a Soft Wearable Digital Spirometry Patch.

Faheem A Karim, Ahmed Tariq, Christopher B Fitzpatrick, Lauren Zhou, Mayte Suárez-Fariñas, Helena Schotland, Linda Rogers, Yoon Jae Lee, Woon-Hong Yeo, Yun Soung Kim

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Faheem A KarimIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.ORCID 0009-0006-6520-1219
Ahmed TariqIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.ORCID 0009-0006-9819-4182
Christopher B FitzpatrickSchool of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0009-0005-8747-5344
Lauren ZhouGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
Mayte Suárez-FariñasIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
Helena SchotlandIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.ORCID 0000-0003-0686-3520
Linda RogersIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
Yoon Jae LeeBioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.ORCID 0000-0002-4159-5966
Woon-Hong YeoGeorge W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.ORCID 0000-0002-5526-3882
Yun Soung KimIcahn School of Medicine at Mount Sinai, New York, NY 10029, USA.ORCID 0000-0002-3892-7560

Funding

Development of an all-in-one soft wearable device for accurate lung function detection and asthma diagnosisR21EB034893 · NIBIB · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI KIM, YUN SOUNG, YEO, WOON-HONG · 2023 to 2023
$445k
NIBIB NIH HHS R21EB034893
6 · The paper itself

Abstract

Spirometry is widely regarded as the clinical gold standard for quantifying lung function. It plays a central role in the diagnosis and management of cardiopulmonary disorders, including asthma and chronic obstructive pulmonary disease (COPD). However, the procedure relies on a forceful and often stressful expiratory maneuver that may cause patient discomfort and require substantial effort, frequently necessitating active coaching and trained personnel to ensure reproducible measurements. In this paper, we present the Digital Spirometry Patch (DSP), a soft, flexible, wearable patch capable of estimating lung function parameters by utilizing low-effort breathing maneuvers. Eighteen participants performed low-effort and forceful breathing maneuvers while wearing the DSP to collect tracheal sound and chest movement signals for spirometric parameter estimation using elastic net and simple linear regression. Using leave-one-subject-out cross-validation, the elastic net models achieved RMSEs of 0.668 L, 0.224 L, and 0.428 L/s for FVC, FEV

Indexed as

Biosensing TechniquesRespiratory Function TestsSpirometryWearable Electronic DevicesAdultFemaleHumansMalecross-validationelastic netfeature extractionFEV1FVClinear regressionPEFspirometrywearable biosensor

Identifiers

PMID42187468
PMCPMC13204607

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.