Evidence map›Paper›PMID 42187458›Full record

ArticleBiosensors2026

Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG Devices.

Zixin Chen, Di Wu, Yuanlin Nie, Junwei Zhang, Guanzhou Liu, Feng He, Long Mo, Liming Peng, Chang Zeng, Zhengchun Liu

Abstract read
In one paragraph

Article in Biosensors, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Zixin ChenSchool of Electronic Information, Central South University, Changsha 410083, China.
Di WuSchool of Electronic Information, Central South University, Changsha 410083, China.
Yuanlin NieSchool of Electronic Information, Central South University, Changsha 410083, China.
Junwei ZhangSchool of Electronic Information, Central South University, Changsha 410083, China.
Guanzhou LiuSchool of Electronic Information, Central South University, Changsha 410083, China.
Feng HeSchool of Mechanical and Electrical Engineering, Central South University, Changsha 410083, China.
Long MoSchool of Xiangya Medicine, Central South University, Changsha 410083, China.
Liming PengSchool of Xiangya Medicine, Central South University, Changsha 410083, China.
Chang ZengSchool of Xiangya Medicine, Central South University, Changsha 410083, China.
Zhengchun LiuSchool of Electronic Information, Central South University, Changsha 410083, China.ORCID 0000-0002-2897-8663

Funding

National Natural Science Foundation of China 62371475
6 · The paper itself

Abstract

To address the issue of motion artifact interference faced by wearable ECG monitoring devices in dynamic environments, this paper proposes an adaptive motion artifact removal framework based on improved Variational Mode Decomposition (VMD). By designing a parameter self-adjustment mechanism and a multi-feature fusion mode selection strategy, the algorithm's adaptability to non-stationary ECG signals and noise separation accuracy are enhanced. Experiments on the MIT-BIH Arrhythmia Database demonstrate that the improved VMD algorithm outperforms traditional wavelet transform, Recursive Least Squares (RLS), and conventional VMD methods in multiple performance metrics. Specifically, the signal-to-noise ratio (SNR) is improved by 5.17 dB, the Percentage Root Mean Squared Difference (PRD) is reduced to 49.13%, the correlation coefficient is increased to 0.88, and high real-time processing capability (Real-Time Processing Ratio, RTR = 22.5) is maintained, meeting the low-latency requirements of wearable devices. Moreover, case studies on pathological recordings (e.g., Wolff-Parkinson-White syndrome and third-degree atrioventricular block) reveal that the improved VMD better preserves clinically significant features such as delta waves and dissociated P waves. Furthermore, a downstream arrhythmia classification task using a CWT-CNN classifier achieves 91.67% accuracy on denoised heartbeats, which is 2.67 percentage points higher than that on raw noisy signals (89.00%), confirming the practical benefit of the proposed preprocessing for AI-based diagnosis. This study provides an effective processing solution for improving the signal quality of wearable ECG monitoring.

Indexed as

ElectrocardiographyWearable Electronic DevicesAlgorithmsArrhythmias, CardiacArtifactsHumansSignal Processing, Computer-AssistedSignal-To-Noise RatioWavelet Analysisadaptive denoisingECG signalmotion artifactsignal processingVariational Mode Decomposition (VMD)wearable devices

Identifiers

PMID42187458
PMCPMC13204741

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.