Evidence map›Paper›PMID 42183117›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions2026

Safety and Effectiveness of the KA Micro Plug for Treatment of Patent Ductus Arteriosus in Preterm Low-Birth-Weight Infants: Retrospective Analysis From a Multicenter Registry.

Peter Guyon, Brent M Gordon, Osamah Aldoss, Bassel Mohammad Nijres, Surendranath R Veeram Reddy, Abhay Divekar, Thomas Forbes, Howaida El-Said

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Peter GuyonJoe DiMaggio Children's Hospital, Hollywood, Florida.
Brent M GordonRady Children's Hospital, University of California San Diego, San Diego, California.
Osamah AldossUniversity of Iowa Health Care Stead Family Children's Hospital, Iowa City, Iowa.
Bassel Mohammad NijresUniversity of Iowa Health Care Stead Family Children's Hospital, Iowa City, Iowa.
Surendranath R Veeram ReddyChildren's Medical Center Dallas, University of Texas Southwestern Medical Center, Dallas, Texas.
Abhay DivekarChildren's Medical Center Dallas, University of Texas Southwestern Medical Center, Dallas, Texas.
Thomas ForbesJoe DiMaggio Children's Hospital, Hollywood, Florida.
Howaida El-SaidRady Children's Hospital, University of California San Diego, San Diego, California.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Transcatheter occlusion of patent ductus arteriosus (PDA) in preterm infants is becoming a preferred approach when medical therapy fails or is contraindicated. This study was conducted to describe real-world clinical outcomes following transcatheter occlusion of PDA with the KA Micro Plug. Methods: This retrospective analysis was conducted using medical records from preterm infants (600-2500 g) with PDA treated with the Micro Plug Set ("KA Micro Plug") across 4 US hospitals (January 1, 2020 to February 28, 2024). The primary safety end point was freedom from major adverse events through 30 days postprocedure; adverse events >30 days were also reported. The primary effectiveness end point was clinical success 6 months postprocedure (absent or trivial PDA shunt confirmed via transthoracic echocardiography). Results: One hundred sixteen patients were analyzed (median age at catheterization: 29.0 days). The primary safety end point was met in 116/116 patients (100%). Clinical success at 6 months was achieved in 70/71 patients (98.6%). Adverse events reported within 30 days of the procedure included pericardial effusion (n = 1), increased tricuspid regurgitation not requiring intervention (n = 2), and device embolization with successful retrieval (n = 1). Coarctation of the aorta (n = 1) was discovered at a 6-month follow-up echocardiogram. Three deaths occurred that were unrelated to the device or procedure. Conclusions: The KA Micro Plug demonstrated a high rate of clinical success and few adverse events. A prospective trial with the goal of approval by the Food and Drug Administration for use in this unique patient population is underway.

Indexed as

KA Micro Pluglow-birth-weight infantpatent ductus arteriosuspreterm infantsurgical ligationtranscatheter occlusion

Identifiers

PMID42183117
PMCPMC13198068

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.