ArticleAnnals of joint2026
Salvaging failed metal-on-metal hip resurfacing with a polyethylene acetabular revision.
Article in Annals of joint, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Metal-on-metal implants have been used extensively for hip resurfacing arthroplasty (HRA). When failure occurs from reaction to metal wear debris, implant loosening or instability, conversion to total hip replacement (THR) has been the most common treatment. Acetabular failure can also be addressed by revision to a polyethylene acetabular component, providing the patient with a functional resurfaced hip, which many patients want. Acetabular revision with an intact femur is difficult and it is not always possible to find a matching polyethylene acetabular component. The objective of this cohort study is to determine the results of acetabular revision from metal to polyethylene. The further objective is to determine if a polyethylene liner 1 mm larger than the femoral component can also be successful. Methods: From 1999 to 2020, the author performed 326 revisions of metal-on-metal acetabular resurfacing implants to an acetabular polyethylene component. In 164 patients, the polyethylene used was 1 mm larger ("mismatch") than the femoral component because a closer match was not available. In 162 patients, there was a direct size match ("match") of the polyethylene to the retained femoral component. In this original review study, patient demographic data and patient-reported outcomes measures were collected using Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), and University of California Activity Score (UCLA). Radiographs and component retrievals were studied for wear. Implant survivorship and need for re-revision were the main indicators of success. Results: The mean follow-up period was 13 years (range, 5-26) for 153 patients in the matched group and 157 patients in the mismatched group. Three patients in each group were lost to follow-up, six patients in the matched group and four in the mismatched group died during the follow-up period. There were seven mismatched and six matched retrievals postmortem or during revision available for wear studies. The mean outcome scores were HOOS 91, HHS 92, and UCLA 7. There were no differences in the results of the outcome measures, complications, implant survivorship, or wear noted on the retrievals between the matched and mismatched groups. There were 9 (5.9%) re-revisions in the matched group and 8 (5.1%) in the mismatched group. Conclusions: Patients treated by exchanging their failed metal-on-metal HRA acetabular component with a polyethylene component had good outcomes and low re-revision rates. The acetabular wear seen on retrievals was low and consistent with a lifetime of use in most but not all cases. The conclusion is that acetabular revision to polyethylene for resurfacing is safe and effective when the size is matched or mismatched by 1 mm. A single surgeon performed all the procedures and others might not achieve these results. Caution is necessary before extending these findings to other procedures such as revision THR.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.