Evidence map›Paper›PMID 42181390›Full record

ArticleCureus2026

Use of an Artificial Intelligence Algorithm to Increase Productivity in Implantable Loop Recorder Monitoring: A Multicentre Observational Study.

Cherry Alexander, Alan Robertson, Sophie Bagnall, Catherine Vaughan, Andrew Saunders, Ken Teh, Faheem A Ahmad

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cherry AlexanderDepartment of Cardiology, Queen Elizabeth University Hospital Glasgow, Glasgow, GBR.
Alan RobertsonDepartment of Cardiology, Ninewells Hospital, Glasgow, GBR.
Sophie BagnallDepartment of Cardiology, West of Scotland Innovation Hub, Glasgow, GBR.
Catherine VaughanDepartment of Cardiology, Queen Elizabeth University Hospital Glasgow, Glasgow, GBR.
Andrew SaundersDepartment of Cardiology, Queen Elizabeth University Hospital Glasgow, Glasgow, GBR.
Ken TehDepartment of Cardiology, Queen Elizabeth University Hospital Glasgow, Glasgow, GBR.
Faheem A AhmadDepartment of Cardiology, Queen Elizabeth University Hospital Glasgow, Glasgow, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInsertable loop recorder (ILR) services are increasingly constrained by high volumes of transmitted episodes, many of which are false, clinically irrelevant, or non-actionable. Cloud-based artificial intelligence (AI) algorithms have the potential to suppress false atrial fibrillation (AF) and pause alerts while preserving clinically relevant events. We present the first real-world impact of an AI algorithm activated across a fixed multicentre ILR cohort.

methodsWe performed a retrospective, multicentre before-and-after cohort analysis of consecutive patients. Eligible patients had continuous ILR monitoring for 12 months before and 12 months after service-wide activation ("switch-on") of the Medtronic AccuRhythm AI platform (Medtronic plc, Galway, Ireland), enabling within-patient comparison. All clinician-facing transmitted alerts were counted in each period. Secondary analyses examined the concentration of alert burden across patients and estimated workflow impact using published time-and-motion data for remote transmission review. Differences in alert counts were tested using paired t-tests, reporting mean paired differences with 95% confidence intervals (CI).  Results: The cohort included 445 patients (Reveal LINQ n=438; LINQ II n=7); 440 (99%) were implanted for syncope (mean age 67±15 years; 49.6% male). Total transmitted alert volume fell from 4,261 pre-AI to 2,509 post-AI (29% reduction). The mean paired within-patient change was -3.94 alerts (95% CI -7.5 to -0.4; p<0.05). Alerts were highly concentrated: 7% of patients generated >90% of alerts, and 104 patients had intermittent disconnection from remote monitoring. Applying established workflow timings (11-13 minutes per remote transmission review) translated the reduction into 185-218 hours of physiologist review time released annually: approximately four hours per week of "virtual physiologist" capacity.

conclusionsIn routine practice, AI activation in a multicentre observational study was associated with a statistically significant reduction in ILR alert burden and a clinically meaningful release of staff capacity. Parallel management of high-alert patients and connectivity optimisation may further amplify the operational benefit.

Indexed as

atrial fibrillation managementdeep learning artificial intelligencedisruptive innovationimplantable loop recorder (ilr)unexplained syncope

Identifiers

PMID42181390
PMCPMC13195407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.