Evidence map›Paper›PMID 42179696›Full record

ArticleJournal of wrist surgery2026

Cadaveric Assessment of Distal Radius Fracture Malrotation During Dorsal Spanning Plate Application.

Taylor Paskey, Mark Ren, Dongyeon J Kim, Susanne M Roberts, Robert J Strauch

Abstract read
In one paragraph

Article in Journal of wrist surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Taylor PaskeyDepartment of Orthopaedic Surgery, Columbia University Medical Center, New York, New York.ORCID 0000-0002-7708-763X
Mark RenDepartment of Orthopaedic Surgery, Columbia University Medical Center, New York, New York.ORCID 0000-0003-0179-3471
Dongyeon J KimDepartment of Orthopaedic Surgery, Columbia University Medical Center, New York, New York.
Susanne M RobertsDepartment of Orthopaedic Surgery, Columbia University Medical Center, New York, New York.ORCID 0009-0004-9130-5367
Robert J StrauchDepartment of Orthopaedic Surgery, Columbia University Medical Center, New York, New York.ORCID 0000-0001-6695-5414

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To assess the effects of pronosupination during indirect distal radius fracture reduction and its role in rotational malalignment during surgical application of a dorsal spanning plate (DSP). Materials and Methods: Twelve cadaveric arms were used. Two Kirshner wires (K-wires) were placed proximal and distal to a surgically created fracture of the distal radius. We secured a DSP to the index metacarpal and then fastened the DSP proximally to the radius in either maximal supination, maximal pronation, or neutral rotation positions. The angles formed by the K-wires were measured in each position of rotation and compared with the baseline. Two sets of these measurements were obtained for each forearm: (1) by rotating the radius distal to the simulated fracture (distal rotation) or (2) by rotating the forearm proximal to the simulated fracture (proximal rotation). Rotation in each position was compared using analysis of variance and Tukey tests. Results: The average malrotation from baseline at the fracture site, overall, was 18 degrees in supination and 12 degrees in pronation. For distal rotation only, the average malrotation compared with baseline was 23 ± 14 degrees in supination and 18 ± 9 degrees in pronation. For proximal rotation, the average malrotation compared with baseline was 6 ± 6 degrees in supination and 9 ± 7 degrees in pronation. Rotating distally produced a statistically greater degree of malrotation compared with proximal rotation ( Conclusion: Application of a DSP to the radius resulted in statistically significant rotation through the fracture site when pronating or supinating distal to the fracture site. This rotation can be mitigated by (1) pronating or supinating the radius proximal to the fracture site when applying the plate to the radius or (2) provisionally clamping the plate to the radius with the forearm in neutral and then pronating the forearm to place the screws into the radius.

Indexed as

cadaver studydistal radioulnar jointdistal radius fracturesdorsal spanning platesmalrotation of distal radius fractures

Identifiers

PMID42179696
PMCPMC13193754

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.