Evidence map›Paper›PMID 42178214›Full record

ArticleVox sanguinis2026

In vivo recovery and in vitro quality assessment of apheresis red blood cells stored for 42 days in non-DEHP disposable sets.

Bethany L Brown, Samatha E Mack, Emily Mason, Michael Wellington, Neeta Rugg, Susanne Marschner, Christina Gloor, Rebecca L Sedjo, Nero Evero, Joseph Rice and 4 more

Abstract read
In one paragraph

Article in Vox sanguinis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Bethany L BrownAmerican Red Cross Biomedical Services, Medical and Scientific Office, Washington, DC, USA.ORCID https://orcid.org/0000-0001-8595-8856
Samatha E MackVitalant Research Institute, Denver, Colorado, USA.
Emily MasonTerumo BCT, Inc., Lakewood, Colorado, USA.
Michael WellingtonAmerican Red Cross Biomedical Services, Medical and Scientific Office, Washington, DC, USA.
Neeta RuggHoxworth Blood Center, Cincinnati, Ohio, USA.
Susanne MarschnerVitalant Research Institute, Denver, Colorado, USA.ORCID https://orcid.org/0000-0002-7862-6201
Christina GloorTerumo BCT, Inc., Lakewood, Colorado, USA.
Rebecca L SedjoTerumo BCT, Inc., Lakewood, Colorado, USA.
Nero EveroTerumo BCT, Inc., Lakewood, Colorado, USA.
Joseph RiceTerumo BCT, Inc., Lakewood, Colorado, USA.
Jeremiah GormanTerumo BCT, Inc., Lakewood, Colorado, USA.
Jack P RhodesTerumo BCT, Inc., Lakewood, Colorado, USA.
Richard CookLifetime Scientific, Inc., Dundas, Canada.
Caroline AlquistHoxworth Blood Center, Cincinnati, Ohio, USA.ORCID https://orcid.org/0000-0001-9352-2585

Funding

Terumo BCT
6 · The paper itself

Abstract

BACKGROUND AND

objectivesDi(2-ethylhexyl) phthalate (DEHP) has been used in blood bag manufacturing for decades, but concern about its potential toxicity has prompted regulatory efforts to eliminate it from medical devices, including blood bags. As manufacturers transition to non-DEHP materials, evaluation is required to ensure blood component quality in modified bag systems. Investigational Trima Accel disposables were developed using plasticizers approved as DEHP alternatives per the European Pharmacopoeia. Red blood cells (RBCs) were collected, and two consecutive studies evaluated in vitro quality and in vivo RBC recovery. STUDY DESIGN AND

methodsLeukoreduced RBCs (LR-RBCs) were stored in Additive Solution 3 (AS-3) at 2-6°C for 42 days. In vitro quality parameters measured on days 0, 35 and/or 42 were assessed against US Food and Drug Administration (FDA) and European Directorate for the Quality of Medicines & HealthCare (EDQM) acceptance criteria. A radiolabelling study evaluated in vivo 24-h RBC recovery using the FDA criteria.

resultsKey FDA criteria were met, including haemolysis, which remained below the acceptable limit throughout 42 days of storage. All EDQM criteria were met except Day 0 haematocrit, with 8 units outside the specified range and the confidence interval (CI) lower bound at 77.6%. All FDA criteria for in vivo 24-h RBC recovery were met.

conclusionApheresis LR-RBCs collected with Trima Accel systems using non-DEHP disposables and stored for 42 days met key FDA and EDQM criteria, with any in vitro parameter failures considered artefactual. Products also met FDA's 24-h in vivo RBC recovery criteria, supporting their use as acceptable transfusable products.

Indexed as

Blood Component RemovalBlood PreservationErythrocytesHemolysisHumansTime Factorsin vivo red cell recoverynon‐DEHP plasticizerred blood cells

Identifiers

PMID42178214
PMCPMC13453911

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.