Evidence map›Paper›PMID 42177740›Full record

ArticleEJNMMI physics2026

Improved attenuation correction registration for FDG PET/CT images using data-driven gating (DDG)-based motion match.

Zoë Wilson, Manjeet Kuhar, Kuan-Hao Su, Robert Johnsen, Kevin M Bradley, Daniel R McGowan

Abstract read
In one paragraph

Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zoë WilsonDepartment of Medical Physics and Clinical Engineering, Oxford University Hospitals Foundation Trust, Oxford, UK.
Manjeet KuharDepartment of Medical Physics and Clinical Engineering, Oxford University Hospitals Foundation Trust, Oxford, UK.
Kuan-Hao SuGE HealthCare, Waukesha, WI, USA.
Robert JohnsenGE HealthCare, Waukesha, WI, USA.
Kevin M BradleyWales Research and Diagnostic PET Imaging Centre, Cardiff University, Cardiff, Wales.
Daniel R McGowanDepartment of Medical Physics and Clinical Engineering, Oxford University Hospitals Foundation Trust, Oxford, UK. daniel.mcgowan@oncology.ox.ac.uk.ORCID http://orcid.org/0000-0002-6880-5687

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAdvancements in PET technologies and reconstruction methods have improved spatial resolution and noise in PET/CT, making respiratory motion artefacts more impactful on image quality. The motion-match CT (MMCT) algorithm estimates the phase of a helical CT and warps it towards the end expiration of a patient's respiratory cycle. This MMCT-attenuation correction (MMCTAC) can then be used to reconstruct whole body FDG PET/CT data. The performance of these images were compared to those reconstructed using the uncorrected clinical standard attenuation correction from helical CT (normAC), indicating the proportion of cases where MMCTAC images could reduce motion artefact and improve lesion detectability.

methodsA sequential cohort of 145 whole-body FDG PET/CT scans was previously evaluated for a data-driven gating study, which identified the gated region of interest (ROI) in 98 high-motion patients. 23 of these high-motion patients had small lesions (n=36) identified in the ROI by a clinician to undergo qualitative analysis comparing the two attenuation correction maps used. PET data were reconstructed using BSREM iterative reconstruction with 3 different portions of the collected data: 1. Ungated 6 min, 2. Ungated 3 min, 3. Quiescent period gated. These reconstructions were generated using normAC or MMCTAC, totaling six reconstructions for semi-quantitative analysis and clinician evaluation. An experienced radiologist ranked the 6 images and scored them on a 5-point Likert Scale for lesion detectability, diagnostic confidence, and image quality.

resultsIn 52% (n=12) of patients with lesions, the clinician ranked all three MMCTAC images higher than the three normAC equivalent reconstructions. Lesion detectability and diagnostic confidence scores retained positive mean differences across the three MMCTAC reconstructions compared to normAC. Similarly, the SUVmax values for 36 lesions demonstrated a significant increase (p < 0.05) for MMCTAC versus normAC images across all three reconstructions.

conclusionsThe MMCT algorithm successfully enables the phase-matching of a helical CT to the PET data to reduce the presence of respiratory motion artefact for FDG PET/CT images. Overall, the motion-matched CTAC image scores demonstrated the algorithm's efficacy at reducing the motion artefacts present in FDG PET/CT images, improving diagnostic capability for assessment of lesions in the thorax and upper abdomen.

Indexed as

Attenuation correctionCTPETRespiratory motion

Identifiers

PMID42177740
PMCPMC13433694

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.