Evidence map›Paper›PMID 42177531›Full record

ArticleBiomedical engineering online2026

Asymmetric tripolar nerve cuff electrode designs for optimizing anodal block of myelinated fibers.

Daniel Tovbis, Ryan G L Koh, Rania Jeong, Paul B Yoo

Abstract read
In one paragraph

Article in Biomedical engineering online, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Daniel TovbisInstitute of Biomedical Engineering, University of Toronto, 170 College St, Room 320, Toronto, M5S 3E3, Canada.
Ryan G L KohInstitute of Biomedical Engineering, University of Toronto, 170 College St, Room 320, Toronto, M5S 3E3, Canada.
Rania JeongDepartment of Mechanical and Industrial Engineering, University of Toronto, 5 King's College Rd, Toronto, M5S 3G8, Canada.
Paul B YooInstitute of Biomedical Engineering, University of Toronto, 170 College St, Room 320, Toronto, M5S 3E3, Canada. paul.yoo@utoronto.ca.

Funding

Canada Foundation for Innovation John Evans Leaders Fund, 31506Natural Sciences and Engineering Research Council of Canada RGPAS-2020-00114, RGPIN-2020-06237
6 · The paper itself

Abstract

purposeAnodal block is a common mechanism used to generate unidirectional activation of myelinated nerve fibers. However, nerve block is often inconsistent and difficult to achieve. In this study, we used a computational model to investigate electrode cuff designs that can be exploited to enhance anodal block.

methodsAsymmetric bipolar and tripolar nerve cuff electrodes were initially tested and validated in a rodent sciatic nerve model. A finite element model was implemented, with physical dimensions approximating a rat sciatic nerve implanted with a flat-interface nerve electrode. The McIntyre-Richardson-Grill model was used to predict the activation, block, and reactivation thresholds of myelinated fibers (diameter = 5.7 to 16 μm) as the stimulation amplitude was increased. In vivo experiments were performed using identical nerve cuff electrodes. The asymmetric electrode designs were subsequently investigated using a human-sized model of a nerve implanted with a cylindrical cuff electrode. Key design parameters included the electrode edge length (EEL), anodic contact width, inter-electrode distance, and current division between primary and secondary anodes.

resultsThe rodent model reproduced blocking properties in both computational and in vivo studies, where maximum anodic block reached 88% and 75% of activated fibers, respectively. Simulations involving the human nerve model identified two critical design parameters that can markedly enhance anodal block. An optimal distal EEL (≤ 1 mm) enhanced the performance of bipolar stimulation (anodic block = 91%), whereas, optimizing the current ratio between the primary:secondary anodes (e.g., 6:4) enhanced nerve block in asymmetric tripolar electrodes (anodic block = 90%).

conclusionThis study presents a set of instructions for optimizing the anodal blocking properties of nerve cuff electrodes, where an asymmetric tripolar design with variable anodic current offers a novel method that can adjust for variability at the nerve electrode interface.

Indexed as

Nerve BlockNerve Fibers, MyelinatedAnimalsElectrodesElectrodes, ImplantedEquipment DesignFinite Element AnalysisHumansRatsSciatic NerveAnesthetized ratAnodal nerve blockComputational modelingDirectional stimulationNerve cuff electrodeNerve electrode interface

Identifiers

PMID42177531
PMCPMC13374333

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.