Evidence map›Paper›PMID 42176099›Full record

ArticleJournal of robotic surgery2026

A novel robot-assisted flexible ureteroscope system(RAFUS): design, learning curve, ergonomics, and preclinical feasibility.

Anjun Zhou, Zhenbang Xu, Peng Yu, Bohan Zhang, Along Mao, Gang Man, Hang Li, Yanbo Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anjun ZhouChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Zhenbang XuChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Peng YuChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Bohan ZhangChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Along MaoChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Gang ManChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China.
Hang LiChangchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, 130033, China. lihang@ciomp.ac.cn.
Yanbo WangDepartment of Urology, First Hospital of Jilin University, Changchun, China. wangyanb@jlu.edu.cn.

Funding

Jilin Provincial Scientific and Technological Development Program 20240302045GXJilin University Concept Validation Project 24GNYZ32
6 · The paper itself

Abstract

Traditional manual flexible ureteroscopy imposes a steep learning curve and severe ergonomic burdens. Furthermore, many existing robotic systems lack integrated optical fiber manipulation. To overcome these limitations, this paper presents the design and evaluation of a novel RAFUS that achieves precise control over four key degrees of freedom, including automated laser fiber delivery, via a miniaturized operating handle. For systematic evaluation via an integrated experimental platform, learning curve analysis was conducted, and a novel mean amplitude spectral density (MASD) metric was combined with Mean Frequency (MNF) to form a robust joint index for ergonomic assessment, followed by in vivo preclinical validation. Experimental results based on an exponential learning model demonstrate that the RAFUS not only significantly shortens the learning curve but also minimizes inter-operator variance, reducing the average exploration time from 435 ± 186.6s to 272 ± 69.9s. With the MASD metric effectively overcoming involuntary mechanical unloading and physiological micro-tremors, the joint evaluation demonstrated severe asymmetric fatigue in manual operations, primarily stressing the bilateral wrists and the right biceps brachii, evidenced by a 17.15% MNF decrease in the latter. Conversely, the robotic mode offers operators improved ergonomics. Finally, in vivo canine renal explorations successfully validated the safety and diagnostic reliability of the device. The proposed RAFUS shortens the learning curve and improves ergonomics, demonstrating potential for clinical translation.

Indexed as

ErgonomicsLearning CurveRobotic Surgical ProceduresUreteroscopesUreteroscopyAnimalsDogsEquipment DesignFeasibility StudiesHumansReproducibility of ResultsErgonomicsFlexible ureteroscopyLearning curvePreclinical studyRobot design

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.