Evidence map›Paper›PMID 42174102›Full record

ArticleScientific reports2026

Synergistic fusion of a multilevel visual transformer in CNN for variable-length volumetric radiographic data analysis and content-based retrieval.

Muhammad Owais, Muhammad Zubair, Taimur Hassan, Divya Velayudhan, Naoufel Werghi, Irfan Hussain

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Muhammad OwaisKhalifa University Center for Autonomous Robotic Systems (KU-CARS), Khalifa University, Abu Dhabi, United Arab Emirates. muhammad.owais@ku.ac.ae.
Muhammad ZubairSchool of Computer Science, University of Galway, H91 TK33, Galway, Ireland.
Taimur HassanDepartment of Applied Artificial Intelligence and Robotics, School of Computer Science and Digital Technologies, Aston University, Birmingham, United Kingdom.
Divya VelayudhanKhalifa University Center for Autonomous Robotic Systems (KU-CARS), Khalifa University, Abu Dhabi, United Arab Emirates.
Naoufel WerghiKhalifa University Center for Autonomous Robotic Systems (KU-CARS), Khalifa University, Abu Dhabi, United Arab Emirates.
Irfan HussainKhalifa University Center for Autonomous Robotic Systems (KU-CARS), Khalifa University, Abu Dhabi, United Arab Emirates. irfan.hussain@ku.ac.ae.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Volumetric radiographic data analysis poses significant challenges due to its 3D structure and variable input lengths. Moreover, the unpredictable distribution of diseased regions, often spanning multiple slices and interspersed with normal tissue within abnormal volumes, further complicates the analysis. Despite advancements, existing 3D volumetric analysis methods predominantly rely on 2D slice selection and expert intervention, limiting scalability and efficiency. Additionally, a prevailing challenge is harmonizing the analysis of volumetric radiographic data with variable length. To address these limitations, we introduce a novel deep learning framework that synergistically fuses a lightweight multilevel vision transformer with a convolutional neural network (CNN). The proposed approach independently extracts and aggregates spatial features from 2D slices while preserving multilevel contextual information. A second-stage recurrent module is further integrated to handle variable-length inputs by leveraging single annotations for complete 3D volumes and exploiting their structural features. Empirical validation of our method is conducted on a composite of three publicly accessible radiographic repositories, demonstrating superiority (p-value < 0.01) over existing alternatives. The results achieved highlight remarkable metrics: 98.54% accuracy, 98.51% F1-score, 98.77% average precision, and 98.25% average recall. To facilitate further research and development, we will publicly release the proposed framework and associated resources, providing a robust foundation for future studies. The implementation and materials is available at our GitHub .

Indexed as

Computer-aided diagnosisMedical content retrievalMedical image analysisPattern recognitionSynergistic deep learningVolumetric radiographic data

Identifiers

PMID42174102
PMCPMC13408909

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.