Evidence map›Paper›PMID 42172860›Full record

ArticleInternational dental journal2026

Biomechanical Effects of Implant-Root Fragment Contact in the Socket Shield Technique: A Finite Element Analysis.

Zhangyan Ye, Yanyan Zhang, Zhongqiang Feng, Guangwei Shangguan, Chen Huang, Xia Chen, Hao Ye

Abstract read
In one paragraph

Article in International dental journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhangyan YeDepartment of Stomatology, The People's Hospital of Pingyang (Pingyang Hospital of Wenzhou Medical University), Wenzhou, 325400 Zhejiang, P.R. China.
Yanyan ZhangDepartment of Stomatology, The People's Hospital of Pingyang (Pingyang Hospital of Wenzhou Medical University), Wenzhou, 325400 Zhejiang, P.R. China.
Zhongqiang FengDepartment of Stomatology, The People's Hospital of Pingyang (Pingyang Hospital of Wenzhou Medical University), Wenzhou, 325400 Zhejiang, P.R. China.
Guangwei ShangguanDepartment of Stomatology, The People's Hospital of Pingyang (Pingyang Hospital of Wenzhou Medical University), Wenzhou, 325400 Zhejiang, P.R. China.
Chen HuangDepartment of Stomatology, The People's Hospital of Pingyang (Pingyang Hospital of Wenzhou Medical University), Wenzhou, 325400 Zhejiang, P.R. China. Electronic address: 916582561@qq.com.
Xia ChenDepartment of Stomatology, Yueqing People's Hospital (Affiliated Yueqing Hospital of Wenzhou Medical University), Wenzhou, 325600, Zhejiang, P.R. China. Electronic address: 240858494@qq.com.
Hao YeInstitute of Digitized Medicine and Intelligent Technology, Wenzhou Medical University, Wenzhou, 325015, Zhejiang, P.R. China. Electronic address: 632204073@qq.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe socket shield technique (SST) is widely applied in implant treatments in aesthetic zones, demonstrating significant advantages in preserving hard and soft tissues. Although SST was developed to maintain alveolar bone and gingival architecture by retaining a buccal root fragment, its biomechanical implications - particularly under direct implant-fragment contact - and the optimal geometric parameters of the shield remain poorly defined.

objectiveThis study utilized finite element analysis to evaluate the biomechanical behaviour of direct implant-root fragment contact in SST.

methodsThree-dimensional finite element models of a maxillary anterior socket shield implant were constructed from cone beam computed tomography data. The residual root fragment was modelled with a uniform thickness of 1.5 mm, a length of 6 mm, and labial arc angles of 60°, 90°, 120°, 150°, and 180° at the alveolar crest level. An insertion torque of 30 N·cm and an occlusal load of 100 N were applied to simulate clinical loading conditions. Stress distribution, peak stress, and displacement in the residual root, periodontal ligament (PDL), implant, and surrounding bone interface were analysed by Abaqus software.

resultsUnder insertion torque of 30 N·cm, the peak stress and displacement of the fragment and PDL decreased as the arc angle of the tooth fragment increased. The peak stress for a 60° fragment was 101.9 MPa, which decreased significantly to 75.48 MPa for a 90° fragment, and further to 69.62 MPa, 67.14 MPa, and 42.43 MPa for 120°, 150°, and 180° fragments, respectively. The stress concentration was located at the fragment area corresponding to the implant neck's maximum diameter. The PDL's peak stress decreased from 4.073 to 1.067 MPa, and fragment displacement decreased from 0.01651 to 0.007814 mm. Under a 100 N occlusal force, as the arc angle increased, the peak stress in the PDL and cortical bone increased, while the peak stress in the fragment and implant decreased. The PDL's peak stress was lowest (1.143 MPa) for a 60° fragment and highest (1.996 MPa) for a 180° fragment, both below the natural tooth's PDL peak stress of 2.472 MPa. Cortical bone stress peaked at 49.74 MPa for a 60° fragment, decreased for 90° and 120° fragments (47.77 and 47.62 MPa, respectively), and then increased significantly for 150° and 180° fragments (50.83 and 64.51 MPa).

conclusionWithin the limitations of this static finite element model, direct contact between the implant and a shield fragment with an arc angle of 120° to 150° appears to provide a favourable biomechanical environment. However, in vivo loading is cyclic and may result in long-term fatigue effects on living tissues and biomaterials that were not investigated in this study. Clinical studies are needed to validate these findings.

Indexed as

Dental Implantation, EndosseousDental ImplantsFinite Element AnalysisTooth RootTooth SocketBiomechanical PhenomenaCone-Beam Computed TomographyDental Stress AnalysisHumansImaging, Three-DimensionalMaxillaPeriodontal LigamentStress, MechanicalTorqueDental ImplantsDental implantationFinite element analysisImmediate dental implant loadingMechanicalSocket shield techniqueStress

Identifiers

PMID42172860
PMCPMC13223945

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.