Evidence map›Paper›PMID 42170144›Full record

ArticleCureus2026

Probability Distribution of Times for Selective Lobar Intubation and Ventilation Using a Novel Subglottic Airway Device: A Mannequin Study.

Dennis Kobuzi, Franklin Dexter, Luiz Maracaja, Roberta Garberi, David W Kaczka

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dennis KobuziAnesthesia, University of Iowa, Iowa City, USA.
Franklin DexterAnesthesia, University of Iowa, Iowa City, USA.
Luiz MaracajaAnesthesiology, Duke University, Durham, USA.
Roberta GarberiAnesthesia, University of Iowa, Iowa City, USA.
David W KaczkaAnesthesia, Biomedical Engineering, and Radiology, University of Iowa, Iowa City, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAcute respiratory distress syndrome (ARDS) is characterized by significant heterogeneity in lung mechanics, leading to ventilation-perfusion mismatch and potential for ventilator-induced lung injury. Selective lobar ventilation offers a tailored approach for managing the impact of such heterogeneity by isolating and ventilating specific lung regions. However, its clinical feasibility, particularly the time needed for intubation, has not been established. This study evaluated the time required for selective lobar intubation and ventilation using a novel airway device in a high-fidelity mannequin. The primary hypothesis was that procedural times would follow a log-normal probability distribution. A secondary hypothesis was that the probability of the procedure exceeding five minutes would be less than 5% at the 95% upper confidence limit, if a log-normal distribution were suitable.

methodsThis was a prospective observational study conducted at a university simulation center. Clinicians were invited to perform endotracheal intubation, followed by selective endobronchial intubation of the left lower lobe on an AirSim Advance Bronchi X mannequin (TruCorp Ltd., Lurgan, UK). Participants used a "tube-thru-tube" technique with video laryngoscopy and fiberoptic bronchoscopy, guided by stepwise visual instructions. Data collected included the total time from tube insertion to successful selective lobar ventilation and the participant's self-reported number of intubations performed in the previous year. The fit of procedural times to log-normal and other distributions was assessed using the Shapiro-Wilk and Pearson chi-square tests.

resultsAmong all 52 participants, there was a poor fit to a log-normal distribution (P = 0.0040). However, the six participants who performed less than five endotracheal intubations in the preceding year had significantly longer times (P = 0.0006). Among the other 46 clinicians, procedural times showed a strong fit to a log-normal distribution (Shapiro-Wilk W = 0.98, P = 0.73), superior to normal or Weibull distributions. The mean time for successful selective lobar intubation was 2.26 minutes. No participant exceeded a five-minute threshold. Utilizing the log-normal model, the calculated 95% upper confidence limit on the probability of exceeding five minutes was 0.02%.

conclusionsThis simulation shows that procedure times for selective lobar ventilation follow a log-normal distribution. This statistical predictability is essential for quantitatively evaluating safety and for designing future clinical trials, including novel ARDS therapies with selective lobar ventilation. The confirmation of the log-normal distribution for an advanced airway task can be applied to other assessments of intubation times to make quantitative comparisons (e.g., ratios of means) and to calculate probabilities of exceeding tolerance limits.

Indexed as

acute respiratory distress syndrome (ards)airway management/methodsgeneralized pivotal methodhigh-fidelity mannequinlobar intubationlog-normal modelprobability distributiontime and motion studytolerance limit

Identifiers

PMID42170144
PMCPMC13188651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.