Evidence map›Paper›PMID 42169085›Full record

ArticleBMC oral health2026

Biomechanical comparison of three-dimensional titanium and CFR-PEEK plates for mandibular subcondylar fracture fixation: a three-dimensional finite element analysis.

Recep Ünal, Yeliz Kılınç

Abstract readComparative Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Recep ÜnalDepartment of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University, Ankara, Türkiye. recepunal@gazi.edu.tr.ORCID 0000-0001-5362-427X
Yeliz KılınçDepartment of Oral and Maxillofacial Surgery, Faculty of Dentistry, Gazi University, Ankara, Türkiye.ORCID 0000-0003-2853-7830

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFixation of mandibular subcondylar fractures presents challenges due to limited surgical access and the small size of the proximal fragment; therefore, single-piece and easily applicable three-dimensional (3D) plates may be considered as an alternative. Although titanium is frequently used as a plate material, it has been reported to have certain clinical and imaging-related limitations. In comparison, Carbon Fiber-Reinforced Polyetheretherketone (CFR-PEEK) has emerged as a favorable alternative for mandibular fracture fixation due to its bone-like elastic properties, radiolucency, and biocompatibility. This study aimed to compare CFR-PEEK and titanium in terms of stress distribution and fixation stability under loading conditions using 3D finite element analysis (FEA).

methodsThree single-piece, 3D plate designs (lambda, rhombic, and trapezoid) were modeled with two materials (titanium alloy and 30% CFR-PEEK), yielding six fixation models of mandibular subcondylar fracture. Two static loading conditions were applied: contralateral molar loading and incisal loading. Von Mises stresses in plates and screws, principal stresses in cortical and cancellous bone, and interfragmentary displacement were calculated.

resultsFor both simulated loading conditions, CFR-PEEK exhibited lower von Mises stresses in plates and screws and lower principal stresses in cortical and cancellous bone than titanium, but showed greater interfragmentary displacement. Contralateral molar loading produced higher stresses and displacement than incisal loading. The lowest von Mises stresses in both plates and screws were observed with the CFR-PEEK lambda plate, whereas bone stresses were lowest and most uniformly distributed with the CFR-PEEK rhombic plate. Interfragmentary displacement was minimal in the titanium lambda model and maximal in the CFR-PEEK trapezoid model.

conclusionsCompared with titanium, CFR-PEEK 3D plate constructs reduced stress concentrations in the fixation hardware and surrounding bone but resulted in greater interfragmentary displacement under both loading conditions. Plate geometry and material choice should balance the clinical priority of rigidity versus stress mitigation.

Indexed as

Bone PlatesFracture Fixation, InternalKetonesMandibular FracturesPolyethylene GlycolsTitaniumBenzophenonesBiomechanical PhenomenaCarbon FiberFinite Element AnalysisHumansPolyether CompoundsPolymersBenzophenonesCarbon FiberKetonesPolyether CompoundspolyetheretherketonePolyethylene GlycolsPolymersTitaniumCFR-PEEKFinite element analysisMandibular subcondylar fractureOpen reduction and internal fixationThree-dimensional miniplateTitanium