ArticleNature communications2026
Contrastive language image pretraining for a cardiac magnetic resonance image embedding with zero-shot capabilities.
Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
Vision-language models trained using self-supervised learning are crucial to reduce the dependency on large volumes of labeled data. However, conventional self-supervised approaches that rely on precise image-text pairing are not always feasible for cardiovascular magnetic resonance imaging (CMR) given its ability to visualize cardiac anatomy, physiology, and microstructure in a single exam. We present CMR-contrastive language image pretraining (CMR-CLIP), a vision language model which treats CMR images as videos to jointly learn embeddings between the images in the study and associated reports. The model is trained on a large dataset consisting of 11,028 studies performed at a single healthcare institution and evaluated on an internal test (N = 2,758) and external dataset (N = 428). CMR-CLIP achieves remarkable performance in real-world clinical tasks, achieving accuracies of 88.5% for non-ischemic cardiomyopathy, 88.0% for ischemic cardiomyopathy, 96.2% for cardiac amyloidosis, and 98.6% for hypertrophic cardiomyopathy, potentially leading to more consistent diagnosis of cardiovascular disease.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.