Evidence map›Paper›PMID 42168155›Full record

ArticleMicrosystems & nanoengineering2026

High-uniformity miniaturized PMUT array with broadband and high-sensitivity for wearable ultrasound imaging.

Xingli Xu, Wanli Yang, Zhenzhen Wang, Yongquan Ma, Yuewu Gong, Zhuochen Wang, Xiaohua Jian, Xiaochun Wang, Sheng Zhou, Wei Pang and 1 more

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Xingli XuState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China.
Wanli YangState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China.
Zhenzhen WangDepartment of Ultrasound, Tianjin Chest Hospital, Tianjin, China.
Yongquan MaState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China.
Yuewu GongPrecision Measurement Research and Development Center, Sun Yat-sen University Nanchang Research Institute, Nanchang, China.
Zhuochen WangCollege of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing, China. zc.wang@buct.edu.cn.
Xiaohua JianInstitute of Functional Materials and Intelligent Manufacturing, Nanjing University, Suzhou, China.
Xiaochun WangInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
Sheng ZhouInstitute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, China.
Wei PangState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China.
Pengfei NiuState Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin, China. niupengfei2018@tju.edu.cn.ORCID http://orcid.org/0000-0002-2482-2311

Funding

National Natural Science Foundation of China (National Science Foundation of China) No.12574514
6 · The paper itself

Abstract

Among the diverse ultrasound transducers deployed in wearable continuous imaging applications, piezoelectric micromachined ultrasonic transducer (PMUT), developed via microelectromechanical system (MEMS) technology, exhibit significant potential for wearable use, owing to their device miniaturization and low power consumption. However, PMUT arrays often suffer from poor imaging performance and no efficient method exists to evaluate large-scale arrays' performance other than post-fabrication measurement. This study proposes a mathematical model of mutual radiation impedance to predict the vibration amplitude of each cell in a PMUT array, thereby guiding optimal cell arrangement for simultaneous enhancement of sensitivity, bandwidth, and acoustic uniformity. The elevation aperture of linear PMUT arrays is reduced based on the beam-formed acoustic output, improving the integration and wearability of rigid silicon-based transducers. An ultra-narrow 64-element linear AlN PMUT array with a 7:1 aspect ratio (1 cm × 0.15 cm, aperture area 0.15 cm²) was fabricated for experimental validation. The device demonstrates a pulse-echo fractional bandwidth exceeding 60% at a center frequency of 7 MHz, along with an image contrast of ~50 dB. Its lateral and axial resolutions are measured to be ~0.26 mm and ~0.25 mm, respectively. Continuous and real-time clear phased-array imaging of multiple superficial organs in volunteers, including carotid artery, thyroid gland, and dorsalis pedis artery, demonstrates the qualified ultrasound performance of our designed PMUT array. Our work establishes a systematic framework for developing large-scale PMUT arrays enabling the realization of wearable ultrasound patch with compact form factor, high fidelity imaging quality, superior spatial resolution and low power consumption.

Identifiers

PMID42168155
PMCPMC13194970

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.