Evidence map›Paper›PMID 42165825›Full record

ReviewRecent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer2026

Quantitative SPECT/CT: Technique and Clinical Applications.

Stijn De Schepper, Tim Van den Wyngaert, Philipp Ritt, Torsten Kuwert

Abstract readReview
PubMed Publisher
In one paragraph

Review in Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Stijn De SchepperDepartment of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium. stijn.deschepper@uza.be.
Tim Van den WyngaertDepartment of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium.
Philipp RittChair for Clinical Nuclear Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Torsten KuwertNuclear Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The continuous development of single photon emission computed tomography (SPECT) over the past 50 years has led to improved image quality and increased diagnostic confidence. The most influential developments include the realization of hybrid SPECT/computed tomography (CT) devices, as well as the implementation of attenuation correction and iterative image reconstruction techniques. These developments have led to a preference for SPECT/CT devices over SPECT-only systems and to the widespread adoption of the former, strengthening the role of SPECT/CT as the workhorse of nuclear medicine imaging.New trends in the ongoing development of SPECT/CT are diverse. For example, whole-body SPECT/CT images, consisting of acquisitions from multiple consecutive bed positions in the manner of PET/CT, are increasingly performed. Additionally, in recent years, some interesting approaches in detector technology have found their way into commercial products. For example, some SPECT cameras dedicated to specific organs employ semiconductor detectors made of cadmium telluride or cadmium zinc telluride, which have been shown to increase the obtainable image quality by offering a higher sensitivity and energy resolution.However, the advent of quantitative SPECT/CT which, like PET, can quantify the amount of tracer in terms of Bq/mL or as a standardized uptake value could be regarded as most important development. It is a major innovation that will lead to increased diagnostic accuracy and confidence, especially in longitudinal studies and in the monitoring of treatment response.The current work comprises two main aspects. At first, physical and technical fundamentals of SPECT image formation are described, and necessary prerequisites of quantitative SPECT/CT are reviewed. Additionally, the typically achievable quantitative accuracy based on reports from the literature is given. Finally some examples of clinical applications which benefit from quantitative SPECT/CT are provided.

Indexed as

NeoplasmsSingle Photon Emission Computed Tomography Computed TomographyTomography, Emission-Computed, Single-PhotonHumansImage Processing, Computer-AssistedClinical SPECTQuantitative imagingQuantitative SPECT/CTSPECT/CTStandardization and harmonization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.