Evidence map›Paper›PMID 42165311›Full record

ArticleGlobal spine journal2026

Accuracy and Safety of a Triad-Dependent Technique for Subaxial Cervical Pedicle Screw Placement: A Prospective Cohort Study.

Mohamed El-Meshtawy, Mahmoud Abdelrahman Saleh, Mariam A Ibrahim, Belal Elnady, Mahmoud Fouad Ibrahim

Abstract read
In one paragraph

Article in Global spine journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mohamed El-MeshtawyDepartment of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.
Mahmoud Abdelrahman SalehDepartment of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.
Mariam A IbrahimOrthopedic and Trauma Rehabilitation Unit, Department of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.
Belal ElnadyDepartment of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.ORCID 0000-0002-4433-2096
Mahmoud Fouad IbrahimDepartment of Orthopedic and Trauma Surgery, Assiut University Hospitals, Faculty of Medicine, Assiut University, Assiut, Egypt.ORCID 0000-0001-6353-3689

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Study DesignProspective single-arm cohort study.ObjectivesCervical pedicle screws (CPS) offer superior biomechanical stability compared with lateral mass screws. However, their widespread adoption is constrained by narrow pedicle safety margins and the potential risk of neurovascular injury. This study aimed to describe the rationale of a novel triad-dependent technique (TDT) for subaxial CPS placement and to evaluate its accuracy and safety.MethodsBetween May 2023 and April 2025, 63 consecutive patients undergoing posterior subaxial (C3-C6) cervical instrumentation at our institution were screened for eligibility. CPS were inserted using the TDT, which integrates individualized morphometric preoperative planning, intraoperative fluoroscopic guidance, and continuous tactile monitoring via mini-laminotomy. Postoperative CT was used to assess screw accuracy using the 2-mm breach classification. Multinomial logistic regression was performed to identify risk factors for breach.ResultsA total of 204 CPS were inserted in 41 patients. No breach was observed in 174 screws (85.3%), while 30 screws (14.7%) demonstrated breach, including 18 medial and 12 lateral violations. No neurovascular complications were observed in this cohort. Pedicle diameter <4 mm significantly increased the risk of both medial and lateral breach, while medial wall thickness showed direction-specific effects on breach risk.ConclusionsThe TDT demonstrates the feasibility of accurate and safe subaxial CPS placement. By integrating individualized morphometric planning with fluoroscopic and tactile safeguards, TDT effectively mitigates both medial and lateral breach risks and may expand the safe application of CPS fixation.

Indexed as

cervical pedicle screwsfreehand techniquepedicle breachscrew accuracysubaxial cervical spine

Identifiers

PMID42165311
PMCPMC13194340

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.