Evidence map›Paper›PMID 42164841›Full record

ArticleJournal of experimental orthopaedics2026

Flexion-dependent differences in tibial rotation measured by navigation and robotic systems during bicruciate-stabilised total knee arthroplasty.

Keizo Wada, Daisuke Hamada, Yasuaki Tamaki, Shota Shigekiyo, Yuto Sugimine, Koichi Sairyo

Abstract read
In one paragraph

Article in Journal of experimental orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Keizo WadaDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.ORCID https://orcid.org/0000-0002-8779-1348
Daisuke HamadaDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.ORCID https://orcid.org/0000-0001-7868-6733
Yasuaki TamakiDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.ORCID https://orcid.org/0000-0001-6395-5494
Shota ShigekiyoDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.ORCID https://orcid.org/0009-0006-3909-0324
Yuto SugimineDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.ORCID https://orcid.org/0000-0001-5304-227X
Koichi SairyoDepartment of Orthopedics, Institute of Biomedical Sciences The University of Tokushima Graduate School Tokushima Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study compared the intraoperative tibial rotational kinematics between navigation-assisted and robotic-assisted bicruciate-stabilised total knee arthroplasty (BCS-TKA). Although both systems can evaluate knee motion intraoperatively, it is unclear whether they provide comparable rotational measurements. We hypothesised that these systems would show different tibial rotation profiles, particularly in deep knee flexion. Methods: This retrospective cohort study included 238 knees that underwent BCS-TKA using an image-free navigation system (Precision N) or an image-free handheld robotic-assisted system (NAVIO or CORI). Tibial rotation relative to the femur was measured intraoperatively through 0° to 120° of knee flexion. Patient-reported outcomes were assessed using the 2011 Knee Society Score (KSS). Discrepancies in rotational display between the systems were evaluated by a preliminary bench test using a synthetic bone model. Groups were compared using the Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. Results: Across all groups, BCS-TKA demonstrated a characteristic pattern of internal rotation in early flexion, slight external rotation in mid-flexion and progressive internal rotation towards deep flexion. At 120° of flexion, tibial internal rotation differed significantly among the three groups ( Conclusions: The robotic platform consistently indicated a more externally rotated tibial position compared to the navigation system, suggesting that the two systems apply different reference orientations for tibial rotation in deep knee flexion during BCS-TKA. Therefore, caution is warranted when comparing intraoperative kinematic data across measurement platforms. Level of Evidence: Level III, retrospective cohort study.

Indexed as

intraoperative kinematicsnavigation systemroboticstotal knee arthroplasty

Identifiers

PMID42164841
PMCPMC13184710

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.