Evidence map›Paper›PMID 42164126›Full record

ArticleEuropean journal of radiology open2026

AI detection of knee joint effusion from radiographs: Comparative accuracy of two commercial algorithms.

Jarno T Huhtanen, Mikko Nyman, Roberto Blanco Sequeiros, Seppo K Koskinen, Tomi K Pudas, Sami Kajander, Pekka Niemi, Hannu J Aronen, Jussi Hirvonen

Abstract read
In one paragraph

Article in European journal of radiology open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Jarno T HuhtanenFaculty of Health and Well-being, Turku University of Applied Sciences, Finland.
Mikko NymanDepartment of Radiology, University of Turku and Turku University Hospital, Turku, Finland.
Roberto Blanco SequeirosDepartment of Radiology, University of Turku and Turku University Hospital, Turku, Finland.
Seppo K KoskinenTerveystalo Inc, Jaakonkatu 3, Helsinki, Finland.
Tomi K PudasTerveystalo Inc, Jaakonkatu 3, Helsinki, Finland.
Sami KajanderDepartment of Radiology, University of Turku, Finland.
Pekka NiemiDepartment of Radiology, University of Turku, Finland.
Hannu J AronenDepartment of Radiology, University of Turku and Turku University Hospital, Turku, Finland.
Jussi HirvonenDepartment of Radiology, University of Turku and Turku University Hospital, Turku, Finland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Knee joint effusion might indicate injury even without bony changes. Automated detection from radiographs could improve the sensitivity of AI algorithms. Purpose: To compare two commercially available AI algorithms, BoneView and RBfracture, in detecting knee joint effusion. Material and Methods: This retrospective study collected 123 lateral knee radiographs. Detection of knee joint effusion by both AI algorithms was compared with two board-certified radiologists with arbitration. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and interobserver agreement (Cohen's Kappa) were calculated. 95% confidence intervals (CI) assessed robustness. McNemar's tests compared sensitivity and specificity between AI algorithms. Results: Knee joint effusion was present in 56% of radiographs. BoneView demonstrated a sensitivity of 0.42 (95% CI: 0.31-0.54), specificity of 1.00 (95% CI: 0.93-1.00), PPV of 1.00 (95% CI: 0.88-1.00), NPV of 0.57 (95% CI: 0.47-0.67), and accuracy of 0.68 (95% CI: 0.59-0.75). RBfracture demonstrated a sensitivity of 0.75 (95% CI: 0.64-0.84), specificity of 0.91 (95% CI: 0.80-0.96), PPV of 0.91 (95% CI: 0.81-0.96), NPV of 0.74 (95% CI: 0.63-0.83), and accuracy of 0.82 (95% CI: 0.74-0.88). Cohen's Kappa was 0.49 (95% CI: 0.35-0.63), indicating moderate agreement between the two AI algorithms. Adding knee joint effusion detection to fracture/dislocation predictions improved sensitivity. Conclusions: Two commercially available AI algorithms demonstrated different operating points for knee joint effusion detection: BoneView achieved high specificity, while RBfracture achieved higher sensitivity. Combining injury and effusion predictions increased sensitivity at the cost of specificity.

Indexed as

Artificial intelligenceJoint effusionKneeRadiograph

Identifiers

PMID42164126
PMCPMC13186055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.