Biomechanical evaluation of biodegradable zinc and polylactide pins for radial head fracture fixation: a human cadaver study.

Julian P Maier, Leon Pohl, Jonas Eck, Benjamin Erdle, Nils Mühlenfeld, Kilian Reising, Michael Seidenstuecker, Hagen Schmal, Ferdinand C Wagner

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Julian P MaierDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany. julian.maier@uniklinik-freiburg.de.
Leon PohlDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Jonas EckDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Benjamin ErdleDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Nils MühlenfeldDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Kilian ReisingDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Michael SeidenstueckerG.E.R.N Tissue Replacement, Regeneration & Neogenesis, Department of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Freiburg, Germany.
Hagen SchmalDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.
Ferdinand C WagnerDepartment of Orthopedics and Trauma Surgery, University Medical Center Freiburg, Hugstetter Str. 55, 79106, Freiburg, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDisplaced or unstable radial head fractures are commonly treated with fragment-preserving fixation to restore joint congruity, maintain stability, and allow early mobilization. Biodegradable implants have become attractive alternatives to metallic implants. However, polymer-based pins may be limited by inferior mechanical strength and a higher risk of secondary loss of reduction. Recently, zinc pins have emerged as a potential alternative, but clinical data and biomechanical testing in human bone models are scarce. This study aimed to compare the biomechanical performance of zinc pins (ZP) and polylactide pins (PP) for the fixation of Mason type II radial head fractures using a human cadaver model.

methodsSixteen human cadaver radii from eight donors were used to create standardized Mason type II radial head fractures. Paired left and right radii from each donor were randomly assigned to fixation with either two 2.0 mm ZP or PP. After fracture fixation, specimens underwent cyclic transverse loading (10 cycles), followed by cyclic axial loading (1,000 cycles) between 15 and 50 N at 0.1 Hz, and final load-to-failure testing with continuously increasing axial load (2 N/s). Construct stiffness, micromotion at the fracture site, axial migration (implant loosening), as well as failure loads at 2 mm displacement and construct failure were recorded. A paired statistical analysis was performed to account for donor-specific variability.

resultsFixation with ZP demonstrated higher construct stiffness (0.77 ± 0.21 vs. 0.33 ± 0.05 kN/mm; p-adj. = 0.028) compared to PP constructs under axial load. Further, lower micromotion at the fracture site (0.05 ± 0.01 vs. 0.10 ± 0.02 mm; p-adj. = 0.042) and higher resistance to progressive loading with higher loads at construct failure were measured in ZP compared to PP (190 ± 44 vs. 116 ± 62 N; p-adj. = 0.042). However, no differences were observed between groups in axial migration (0.36 ± 0.08 mm vs. 0.36 ± 0.08 mm) during cyclic testing, indicating comparable resistance to implant loosening. Notably, construct stiffness under transverse loading and the loads required to reach a clinically relevant fracture displacement of 2 mm (161 ± 37 vs. 112 ± 60 N; p-adj. = 0.116) did not differ between ZP and PP constructs, suggesting adequate stability of both constructs within functional loading ranges.

conclusionIn this cadaveric biomechanical study, zinc pins provided superior overall mechanical stability compared with polylactide pins for fixation of Mason type II radial head fractures, suggesting they are a promising alternative to the widely used polylactide pins. Importantly, polylactide pins also demonstrated sufficient primary stability without increased implant loosening or reduced resistance to clinically relevant fracture displacement. However, based on our data, zinc pins demonstrated favorable biomechanical performance in terms of construct stiffness and load to failure, offering a greater mechanical safety margin. Further clinical studies are required to evaluate in vivo performance and long-term outcomes of zinc-based biodegradable implants.

Indexed as

Absorbable ImplantsBone NailsFracture Fixation, InternalPolyestersRadial Head and Neck FracturesZincAgedAged, 80 and overBiomechanical PhenomenaCadaverFemaleHumansMaleMaterials TestingMiddle AgedPolyesterspoly(lactide)ZincBiodegradable implantsBiomechanicsHuman cadaverPolylactide pinsRadial head fractureZinc pins

Identifiers

PMID42163383
PMCPMC13200317

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.