Evidence map›Paper›PMID 42154210›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

A Granular Interaction Framework for Surgical Robotic Digital Twins: Enabling Realistic Segment-Level Manipulation in Extended Reality.

An-Nhien Vo, Dhanakumaresh Subramani, Joachim Schmidt, Jan Arensmeyer, Philipp Feodorovici

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

An-Nhien VoDepartment of Thoracic Surgery, University Hospital Bonn, Bonn, Nordrhein-Westphalia, Germany. an.vo@ukbonn.de.ORCID http://orcid.org/0009-0006-8182-4483
Dhanakumaresh SubramaniDepartment of Thoracic Surgery, University Hospital Bonn, Bonn, Nordrhein-Westphalia, Germany.
Joachim SchmidtDepartment of Thoracic Surgery, University Hospital Bonn, Bonn, Nordrhein-Westphalia, Germany.
Jan Arensmeyer *Department of Thoracic Surgery, University Hospital Bonn, Bonn, Nordrhein-Westphalia, Germany.
Philipp Feodorovici *Department of Thoracic Surgery, University Hospital Bonn, Bonn, Nordrhein-Westphalia, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionWhile Robot-Assisted Surgery (RAS) offers significant clinical advantages, adoption is often hindered by steep learning curves. Extended Reality (XR) and Digital Twins (DT) provide promising solutions for surgical training. However, existing integration pipelines require high-fidelity system-level simulations that address complex kinematic constraints. This paper proposes a modernized framework for integrating RAS into Extended Reality (XR) by transitioning from CAD models to scan-derived digital twins (DTs), as well as a force-based interaction paradigm for realistic simulation.

methodsPerformance profiling was conducted on the Apple Vision Pro (AVP) to establish empirical hardware benchmarks for polygon counts. Utilizing 3D scanning and manual retopology, we developed a digital surrogate of the Dexter Surgical Robotic System, prioritizing model fidelity within stand-alone XR constraints. Within Unity, we evaluated Rigidbody versus ArticulationBody physics for kinematic stability. This necessitated the development of a force-based interaction system supporting both linear feedback (PD) and geometric constraint-based controllers.

resultsThe scan-derived model achieved a spatial accuracy of 1.6mm relative to the physical system. ArticulationBody physics demonstrated superior numerical stability compared to traditional Rigidbody components. While the linear feedback controller showed higher quantitative precision, it required extensive manual gain tuning; conversely, the geometric constraint-based controller provided high-speed stability without iterative calibration.

conclusionThis framework modernizes RAS integration by providing a non-CAD-dependent workflow, a prescriptive testing protocol for mesh decimation, and a force-based interaction system that enhances kinematic realism for clinical training.

Indexed as

Digital operating roomDigital twinExtended realityGeometric representationInteraction systemSurgical robotic system

Identifiers

PMID42154210

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.