Evidence map›Paper›PMID 42148898›Full record

ArticleAnalytical chemistry2026

Quantitative Multiplex Digital PCR with Fluorescence-Encoded Nanoreactor Beads.

Stephan Hubold, Lea Kanitz, Oliver Lemuth, Ines Engelmann, Susanne Toepfer, Susanne Brandes, Theresa Liebe, Friederike Fritsch, Sascha Braun, Martin Reinicke and 2 more

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Stephan HuboldBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Lea KanitzBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Oliver LemuthBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Ines EngelmannBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Susanne ToepferBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Susanne BrandesBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Theresa LiebeBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Friederike FritschBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.
Sascha BraunLeibniz Institute of Photonic Technology, Member of the Research Alliance "Leibniz Health Technologies" and the Leibniz Centre for Photonics in Infection Research (LPI), Albert-Einstein-Straße 9, 07745 Jena, Germany.
Martin ReinickeLeibniz Institute of Photonic Technology, Member of the Research Alliance "Leibniz Health Technologies" and the Leibniz Centre for Photonics in Infection Research (LPI), Albert-Einstein-Straße 9, 07745 Jena, Germany.
Ralf EhrichtLeibniz Institute of Photonic Technology, Member of the Research Alliance "Leibniz Health Technologies" and the Leibniz Centre for Photonics in Infection Research (LPI), Albert-Einstein-Straße 9, 07745 Jena, Germany.
Eugen ErmantrautBLINK AG, Bruesseler Strasse 20, 07747 Jena, Germany.ORCID 0000-0001-6876-0565

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Syndromic PCR panels are becoming a pivotal diagnostic tool in precision medicine. Yet, the design and validation of such test panels is cumbersome, and the integration of new markers typically necessitates complete panel revalidation, a challenge that becomes even more complex for quantitative assays. Here, we introduce a novel multiplex digital PCR strategy utilizing fluorescence-encoded magnetic Nanoreactor Beads (femNRB), enabling cross-reactivity-free detection and absolute quantification of multiple genetic markers within a single sample. These uniquely encoded nanoreactor beads are reversibly conjugated to target-specific primers and probes, allowing the formation of highly adaptable panels composed of multiple PCR assays. As proof of concept, we assembled and validated a 10-assay panel targeting species-specific markers for common nosocomial pathogens. We subsequently expanded this panel with six additional markers for antibiotic resistance and virulence, systematically evaluating both configurations. Remarkably, without further optimization, both panels demonstrated equivalent analytical performance, underscoring the robustness and scalability of this method. This approach operates without complex microfluidic hardware and represents a diagnostic multiplex digital PCR platform that enables seamless assay integration while maintaining uncompromised quantification across variable sample concentrations. By eliminating the need for recalibration, this method substantially simplifies assay expansion, providing a powerful, modular solution for developing and upgrading diagnostic test panels with minimal effort.

Indexed as

Fluorescent DyesMultiplex Polymerase Chain ReactionFluorescenceMicrospheresFluorescent Dyes

Identifiers

PMID42148898
PMCPMC13234817

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.