Evidence map›Paper›PMID 42147950›Full record

ArticleQuantitative imaging in medicine and surgery2026

Clinical application of a full free-breathing cardiac MRI protocol: feasibility, efficiency, and diagnostic accuracy.

Yan Chen, Wei Chen, Ke Xue, Jiahuan Dai, Yifeng Gao, Yuqi Wang, Yike Zhao, Hui Wang, Lei Xu

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yan Chen *Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Wei Chen *Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Ke XueMR Research Collaboration, Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China.
Jiahuan DaiMR Research Collaboration, Beijing United Imaging Research Institute of Intelligent Imaging, Beijing, China.
Yifeng GaoDepartment of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Yuqi WangDepartment of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Yike ZhaoDepartment of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Hui WangDepartment of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Lei XuDepartment of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Conventional cardiac magnetic resonance imaging (MRI) protocols require multiple breath-holds (BHs) for each sequence, limiting their widespread clinical application. This study sought to develop a full free-breathing (FB) cardiac MRI protocol, including cine imaging, T2 weighted imaging (T2WI), and late gadolinium enhancement (LGE) imaging, and to assess its clinical feasibility. Methods: A total of 94 patients who underwent paired BH- and FB-acquired cine imaging, T2WI, and LGE imaging at 3.0T were prospectively included in the study. The primary analysis included image quality (IQ), qualitative assessment of myocardial edema and enhancement, and quantification of biventricular function and LGE. The overall IQ of all sequences was visually evaluated using a five-point Likert scale. Blood to myocardial contrast (BMC) was measured to quantitatively evaluate the IQ of the short-axis cine sequence. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated to evaluate the IQ of the T2WI and LGE sequences. Function parameters, including left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and left ventricular (LV) mass, were measured and compared. Results: The proposed full FB protocol achieved identical diagnoses in all patients. The total scan time of all FB sequences was significantly shorter than that of all BH sequences (551±194 Conclusions: A FB cardiac MRI protocol is feasible in clinical practice, providing shorter acquisition times, comparable IQ, and highly accurate qualitative and quantitative results.

Indexed as

cinefree-breathing (FB)late gadolinium enhancement (LGE)Magnetic resonance imaging (MRI)T2 weighted imaging (T2WI)

Identifiers

PMID42147950
PMCPMC13178324

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.