Evidence map›Paper›PMID 42147944›Full record

ArticleQuantitative imaging in medicine and surgery2026

Evaluation of optimal ClearInfinity artificial intelligence deep learning reconstruction algorithm weights with a 70-kVp tube voltage combined with "dual-low" abdominal computed tomography angiography.

Jialin Xiang, Sai Wang, Chao Liu, Hongmei Liu, Pengyu Zhu, Guan Wang, Wen Chen

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jialin XiangDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.
Sai WangDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.
Chao LiuDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.
Hongmei LiuDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.
Pengyu ZhuDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.
Guan WangCT Clinical Cooperation Center (CTCC), Neusoft Medical Systems Co., Ltd., Shenyang, China.
Wen ChenDepartment of Radiology, Taihe Hospital, Hubei University of Medicine, Shiyan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Abdominal computed tomography angiography (CTA) often requires a high tube voltage and relatively large contrast volume to ensure adequate vascular enhancement, which increases radiation exposure and contrast-related risks. Deep learning reconstruction techniques have demonstrated potential to improve image quality under low-dose acquisition conditions. This study evaluated a 70-kVp abdominal CTA protocol using low tube voltage and low contrast medium volume ("dual-low"), reconstructed with ClearInfinity (Neusoft Medical) at different weighting levels. Methods: A prospective study was conducted on 100 patients undergoing abdominal CTA who were divided into two groups: group A (70 kVp, 40-45 mL of contrast medium, and a flow rate of 2.0-2.5 mL/s) and group B (conventional 100-kVp protocol, 60-70 mL of contrast medium, and a flow rate of 3.0-3.5 mL/s). Group B served as standard-dose reference, and its images were reconstructed using the vendor-recommended ClearView iterative reconstruction. Images in Group A were reconstructed with ClearInfinity at four weighting levels-30%, 50%, 70%, and 90%-which corresponded to groups A1 to A4, respectively. Radiation dose parameters, including computed tomography dose index volume (CTDIvol), dose-length product (DLP), and effective dose (ED) were recorded and analyzed for both groups. Objective evaluation included CT attenuation, image noise (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Subjective image quality was independently evaluated by two radiologists. Results: The CTDIvol, DLP, and ED in group A were significantly lower than those in group B (P<0.001). Mean vascular attenuation did not differ significantly between the groups (P>0.05). As the ClearInfinity weighting increased from 30% to 90%, image noise progressively decreased, whereas both the SNR and CNR progressively increased. Compared with the iterative reconstruction group (group B), group A4 exhibited a lower SD and higher SNR and CNR across major abdominal vessels (all P values <0.05). Subjective image quality increased from A1 to A2 and then remained stable at higher ClearInfinity weights, with no significant differences across groups A2-A4. Interobserver agreement for subjective scoring was excellent (κ>0.81). Conclusions: A 70-kVp abdominal CTA protocol reconstructed with 90% ClearInfinity weighting provides substantial radiation dose reduction while preserving diagnostic vascular image quality despite reduced contrast volume.

Indexed as

abdominal computed tomography angiography (abdominal CTA)ClearInfinity reconstructionDeep learningimage qualityradiation dose