Influence of image preprocessing on reproducibility and longitudinal repeatability analysis of radiomics features in magnetic resonance image-guided accelerator imaging.
Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Radiomics has emerged as a promising approach for extracting quantitative features from medical images to support tumor characterization and treatment response assessment. With the increasing use of magnetic resonance-guided linear accelerator (MR-Linac), ensuring the stability and reproducibility of radiomics features derived from magnetic resonance imaging (MRI) has become critical for reliable clinical applications. However, image preprocessing parameters may substantially influence feature stability. Therefore, this study aimed to evaluate the effects of image preprocessing parameters on radiomics feature stability in MRI acquired on a 1.5T MR-Linac system, with specific assessment of test-retest repeatability, longitudinal repeatability, and inter-platform reproducibility. Methods: MRI datasets were acquired using the American College of Radiology (ACR) phantom on 1.5T MR-Linac systems for test-retest, longitudinal, and inter-platform analysis. The T1-weighted (T1w), T2-weighted (T2w), and fluid-attenuated inversion recovery (FLAIR) sequences were collected. Five regions of interest were delineated on T1w images and propagated to corresponding T2w and FLAIR sequences. Image preprocessing strategies included voxel resampling (multiple isotropic resolutions), intensity normalization (none or Z-score), and intensity discretization using bin width (BW) or bin number (BN). Feature stability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV). Features with ICC values >0.9 and CV values <10% were considered robust. Results: Optimal preprocessing strategies varied across imaging sequences and evaluation tasks. In the test-retest analysis, the proportion of robust features reached 85.87% for T1w, 89.13% for T2w, and 90.22% for FLAIR sequences under optimal settings. In contrast, longitudinal repeatability and inter-platform reproducibility showed substantially lower stability, with robust feature proportions ranging from 42.39% to 76.09% across sequence and preprocessing configurations. Larger voxel sizes (>2 mm isotropic) consistently reduced stability across all tasks. The BN discretization method generally yielded higher proportions of robust features than the BW method; however, this advantage was sequence- and task-dependent. Z-score normalization had minimal effect when applied with BN discretization, but reduced feature stability when combined with the BW discretization. Conclusions: Image preprocessing parameters significantly influence the stability of radiomics features acquired on MR-Linac. Stability varies considerably between test-retest repeatability and longitudinal repeatability or inter-platform reproducibility. Task- and sequence-specific optimization of preprocessing strategies is therefore essential before clinical implementation. Further validation in clinical datasets is acquired to support robust integration of MR-Linac radiomics into adaptive radiotherapy workflows.