Evidence map›Paper›PMID 42147694›Full record

ArticleCureus2026

Accuracy Assessment of Planned Versus Actual Trajectories in Robotic-Assisted Spine Surgery Utilizing Perioperative O-Arm CT Scans.

Mirant B Dave, Mikeson Panthackel, Bharatkumar R Dave, Ajay Krishnan, Shivanand C Mayi, Ravi Ranjan Rai, Arjit Vashishtha, Amritesh Singh, Saurabh S Kulkarni, Yogenkumar Adodariya

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Mirant B DaveSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Mikeson PanthackelSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Bharatkumar R DaveSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Ajay KrishnanSpine, Bhavnagar Institute of Medical Sciences (BIMS), Bhavnagar, IND.
Shivanand C MayiSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Ravi Ranjan RaiSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Arjit VashishthaSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Amritesh SinghSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.
Saurabh S KulkarniOrthopaedics, Mahatma Gandhi Medical College and Research Institute, Aurangabad, IND.
Yogenkumar AdodariyaSpine Surgery, Stavya Spine Hospital and Research Institute, Ahmedabad, IND.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Study design A prospective cohort study. Objectives To find the deviations in entry point, axial angulation, and sagittal angulation between the planned trajectories versus the achieved trajectories in Mazor-X robotic spine surgery. Methods This study was conducted from December 2023 to June 2025, including 250 patients undergoing robotic-assisted pedicle screw fixation. Planned and actual screw trajectories were compared using perioperative O-arm CT scans. Results A total of 1170 screws were inserted (96 thoracic, 1074 lumbar). Mean entry deviation was 2.27 ± 1.5 mm, axial angular deviation 3.7° ± 3.7°, and sagittal deviation 3.4° ± 3.2°. A clinically acceptable placement rate of 99.7% was achieved, with only four breaches requiring revision. Operative time and screw insertion time decreased with experience, reflecting a short learning curve. Conclusion Robotic guidance using the Mazor X Stealth Edition (Medtronic, 2018, Memphis, Tennessee) ensures highly accurate and safe pedicle screw placement in spine surgery.

Indexed as

accuracymazor xminimally invasive spine surgerypedicle screwrobotics

Identifiers

PMID42147694
PMCPMC13179850

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.