ArticleFrontiers in oncology2026
Assessment of the mechanical performance of a novel CT-linac treatment couch.
Article in Frontiers in oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: This study aims to systematically evaluate the mechanical performance of the novel treatment couch for the uLinac VisionaryTx CT-Linac (United Imaging Healthcare, China). Materials and methods: Quality assurance protocols were developed by integrating AAPM TG-142 and TG-66 guidelines. The following key parameters were assessed: (1) couch top movement accuracy, including translational/rotational precision and perpendicularity to the CT imaging plane; (2) couch top rigidity under varying loads (0-135 kg) and extensions; (3) couch base movement accuracy, covering longitudinal travel reproducibility and rotational homing; (4) efficacy of the laser rangefinder-based sag correction and the stability of the rangefinder itself; and (5) comprehensive end-to-end evaluation of IGRT workflows to determine the overall impact of couch mechanical performance on delivery accuracy. All tests were conducted under clinically representative loaded conditions. Results: The couch top demonstrated high accuracy in translational movement (≤ 0.5 mm), rotation (< 0.12°), and perpendicularity relative to the CT imaging plane. Under maximum load, the couch top showed a sag of 4.1 mm, demonstrating superior rigidity to a dedicated CT simulator while being slightly less rigid than conventional linac couches. The couch base achieved precise longitudinal movement (≤ 1 mm) and rotational homing accuracy (< 0.1°). The laser rangefinder-based correction method achieved good agreement between calculated and measured height variations (deviation < 0.6 mm) with excellent stability in both angular and distance measurements. End-to-end tests verified sub-millimeter (0.5 mm) and sub-degree (0.5°) accuracy for IGRT workflows across various loading conditions. Conclusion: The novel CT linac couch system (uLinac VisionaryTx) exhibits exceptional mechanical performance and fully satisfies the precision requirements for CT acquisition, image guidance, and setup error correction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials