Evidence map›Paper›PMID 42146577›Full record

ArticlebioRxiv : the preprint server for biology2026

Design of a Conductive Hydrogel Coating to Improve Catheter-Tissue Coupling in Radiofrequency Ablation.

Derek Bashe, Octavio Jalife, Archita Duvvada, Bhanaviya Venkat, Lukas Jaworski, Drew Bernard, Mathews John, Allison Post, Mehdi Razavi, Elizabeth Cosgriff-Hernandez

Abstract readPreprint
In one paragraph

Article in bioRxiv : the preprint server for biology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Derek BasheDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA.
Octavio JalifeDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA.
Archita DuvvadaDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA.
Bhanaviya VenkatDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA.
Lukas JaworskiThe Texas Heart Institute, Baylor College of Medicine, Houston, Texas, 77030, USA.
Drew BernardThe Texas Heart Institute, Baylor College of Medicine, Houston, Texas, 77030, USA.
Mathews JohnThe Texas Heart Institute, Baylor College of Medicine, Houston, Texas, 77030, USA.
Allison PostThe Texas Heart Institute, Baylor College of Medicine, Houston, Texas, 77030, USA.
Mehdi RazaviThe Texas Heart Institute, Baylor College of Medicine, Houston, Texas, 77030, USA.
Elizabeth Cosgriff-HernandezDepartment of Biomedical Engineering, The University of Texas at Austin, Austin, Texas, 78712, USA.

Funding

Injectable Hydrogel Electrodes to Prevent Ventricular ArrhythmiasR01HL162741 · NHLBI · UNIVERSITY OF TEXAS AT AUSTIN · PI Elizabeth Marie Cosgriff-Hernandez, Mehdi Razavi · 2023 to 2026
$2.4M
NHLBI NIH HHS R01 HL162741
6 · The paper itself

Abstract

Radiofrequency ablation is a mainstay of cardiac rhythm management despite high recurrence rates. Current radiofrequency ablation catheters are limited by poor contact with trabeculated cardiac tissue that promotes uneven heating with hot spots that cause collateral damage and regions of incomplete ablation that promote recurrence. Herein, we report on a conductive hydrogel coating of radiofrequency ablation catheters to improve tissue contact while promoting efficient energy transfer. A method was developed to graft a polyether urethane diacrylamide hydrogel to the distal tip of the catheter that maintained stable adhesion following drying, sterilization, and rehydration. The coating also remained intact after passage through an introducer sheath and 50 cycles of radiofrequency ablation at clinical power. The hydrogel-coated catheter demonstrated enhanced tissue contact that was dependent on hydrogel modulus. Hydrogel-mediated ablation prevented steam pop incidence and generated homogeneous lesions in an ex vivo ablation model; however, increased hydrogel conductivity is needed to achieve comparable lesion dimensions as the bare metal catheter and prevent coating damage at higher power. Collectively, these results establish a tunable hydrogel coating method that addresses limitations of conventional radiofrequency ablation and offers a promising approach to enhance the safety and efficacy of cardiac ablation therapies.

Indexed as

Cardiac arrhythmiaConductive hydrogelsHydrogelsRadiofrequency ablation

Identifiers

PMID42146577
PMCPMC13174546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.