Evidence map›Paper›PMID 42145658›Full record

ArticleAntibody therapeutics2026

Application of a novel LC-MS-based proteomic workflow for host cell protein monitoring and risk control in biotherapeutics.

Xiaojuan Yu, Jianhui Cheng, Qianchuan Lv, Feiyu Wang, Jianzhong Hu, Xinxin Li, Chuanfei Yu

Abstract read
In one paragraph

Article in Antibody therapeutics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiaojuan YuState Key Laboratory of Drug Regulatory Science, NHC Key Laboratory of Research on Quality and Standardization of Biotech Products, NMPA Key Laboratory for Quality Research and Evaluation of Biological Products, National Institutes for Food and Drug Control, Beijing 100061, China.
Jianhui ChengState Key Laboratory of Neurology and Oncology Drug Development, Nanjing 210042, China.ORCID https://orcid.org/0009-0004-1061-4652
Qianchuan LvState Key Laboratory of Neurology and Oncology Drug Development, Nanjing 210042, China.
Feiyu WangState Key Laboratory of Drug Regulatory Science, NHC Key Laboratory of Research on Quality and Standardization of Biotech Products, NMPA Key Laboratory for Quality Research and Evaluation of Biological Products, National Institutes for Food and Drug Control, Beijing 100061, China.
Jianzhong HuState Key Laboratory of Neurology and Oncology Drug Development, Nanjing 210042, China.
Xinxin LiState Key Laboratory of Neurology and Oncology Drug Development, Nanjing 210042, China.
Chuanfei YuState Key Laboratory of Drug Regulatory Science, NHC Key Laboratory of Research on Quality and Standardization of Biotech Products, NMPA Key Laboratory for Quality Research and Evaluation of Biological Products, National Institutes for Food and Drug Control, Beijing 100061, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Comprehensive monitoring of host cell proteins (HCPs) is essential for ensuring the quality, safety, and consistency of antibody therapeutics. Conventional enzyme-linked immunosorbent assay-based assays provide only total HCP burden and lack the resolution to identify individual, functionally active impurities that may affect product stability or efficacy. To address this limitation, we developed a versatile, high-sensitivity mass spectrometry-based workflow capable of molecular-level HCP characterization and risk assessment. Methods: We developed and evaluated a sub-ppm, easy-to-use liquid chromatography-mass spectrometry-based proteomics workflow for the identification and relative quantitation of HCPs across downstream purification and final formulation, which offers molecular-specific, risk-based process characterization and regulatory-aligned quality assurance for antibody therapeutics. Results: The workflow demonstrated sub-ppm sensitivity and excellent reproducibility, enabling comprehensive tracking of HCP clearance across the purification process. Scale-up from 100 to 500 L led to higher total HCP levels and moderately increased species diversity, indicating reduced clearance efficiency and altered impurity profiles. Mechanistic interpretation linked transient thioredoxin and thioredoxin reductase presence to disulfide bond reduction and nonreducing capillary electrophoresis-sodium dodecyl sulfate purity fluctuations. In the formulation stage, lipoprotein lipase was identified as a key contributor to polysorbate 80 (PS80) degradation, consistent with accelerated stability results, leading to successful process optimization. Conclusions: This study establishes a comprehensive, sub-ppm data-independent acquisition (DIA)-mass spectrometry (MS) platform for HCP monitoring in antibody therapeutics, bridging analytical characterization with process and formulation control. The workflow enables molecular-level understanding of impurity behavior, supports proactive risk mitigation, and enhances overall process consistency, representing a significant advancement in HCP management and biotherapeutic quality assurance.

Indexed as

bioprocess monitoringhost cell proteinsnanoLC–DIA-MSnative digestionrisk control

Identifiers

PMID42145658
PMCPMC13175985

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.