Evidence map›Paper›PMID 42145318›Full record

ArticleThe archives of bone and joint surgery2026

Improving Biocompatibility and Mechanical Properties of Titanium Implants in Orthopedic Surgeries: The Role of Machining Depth in Enhancing Surface Interaction with Bone Tissue.

Sayyed Mohammadreza Sedehi, Mohammadreza Farahani

Abstract read
In one paragraph

Article in The archives of bone and joint surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Sayyed Mohammadreza SedehiSchool of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran.
Mohammadreza FarahaniSchool of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: This study comprehensively examined the influence of cutting depth during dry milling on the structural, mechanical, and biocompatibility characteristics of commercially pure titanium. The primary objective was to evaluate how variations in cutting depth can alter the crystallite size, microstrain, and wear resistance, as well as to investigate their correlation with essential biocompatibility parameters including cellular interactions, osteointegration potential, and corrosion resistance in a simulated body fluid environment. Understanding these interrelations is crucial for improving the overall performance of titanium implants used in biomedical applications. Methods: Pure titanium specimens were precisely machined at cutting depths of 0.1, 0.2, and 0.3 mm under dry conditions, ensuring that all other machining parameters remained constant. The structural characteristics were analyzed using X-ray diffraction to determine crystallite size and microstrain variations. Wear resistance was evaluated through sliding wear tests that quantified material loss, while biocompatibility performance was assessed via immersion tests in simulated body fluid. This evaluation included corrosion resistance measurements, quantification of calcium-phosphate deposition on the surface, and analysis of the initial interactions with osteoblast-like cells to determine cellular affinity and bioactivity. Results: The experimental results indicated that increasing the cutting depth led to a significant reduction in crystallite size (28, 50, and 25 nm for 0.1, 0.2, and 0.3 mm, respectively) and a corresponding increase in microstrain (0.0011, 0.0011, and 0.009). Specimens machined at cutting depths of 0.2 and 0.3 mm exhibited superior wear resistance, with lower weight losses (7.9 and 5.3 mg) compared with the 0.1 mm specimen (12.1 mg). Biocompatibility assessments revealed that higher cutting depths enhanced corrosion resistance, promoted calcium-phosphate deposition, and improved osteointegration potential. Conclusion: optimizing the cutting depth to 0.2-0.3 mm during dry milling can substantially improve both mechanical performance and biocompatibility, offering valuable guidance for implant manufacturing and long-term in vivo functionality.

Indexed as

BiocompatibilityMachiningSimulated body fluid (SBF)Titanium

Identifiers

PMID42145318
PMCPMC13179538

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.