SynthesisThe Cochrane database of systematic reviews2026
Thromboelastography (TEG) or thromboelastometry (ROTEM) to monitor haemostatic treatment versus usual care in adults or children with bleeding.
Synthesis in The Cochrane database of systematic reviews, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Trauma-Induced Coagulopathy: From Endotheliopathy and Fibrinolysis Phenotypes to Viscoelastic-Guided Resuscitation.European journal of haematology · 2026Review
Corrections and comments
- Update of
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSevere bleeding and coagulopathy are serious clinical conditions that are associated with high mortality. Thromboelastography (TEG) and thromboelastometry (ROTEM) are increasingly used to guide transfusion strategy, but their roles remain disputed. This is an update of a review that was first published in 2011 and updated in January 2016.
objectivesThe objective was to evaluate the benefits and harms of TEG-/ROTEM-guided transfusion strategies for bleeding in adults and children by comparing TEG-ROTEM-guided transfusion with standard treatment. SEARCH
methodsIn this updated review, we identified randomised controlled trials (RCTs) from the following electronic databases: Cochrane Central Register of Controlled Trials (CENTRAL); Ovid MEDLINE(R) ALL; Embase; Web of Science Core Collection and Biosis Previews via Clarivate; CINAHL EBSCO; and the WHO Global Index Medicus incl. LILACS (from 2015 up to 5 January 2025). We searched for ongoing clinical trials and unpublished studies in the following registries during the aforementioned period: ISRCTN, ClinicalTrials.gov, CentreWatch, and UMIN-CTR. We contacted trial authors, authors of previous reviews, and manufacturers in the field. The original searches were run in October 2010 and January 2016. SELECTION CRITERIA: We included all RCTs, irrespective of blinding or language, that compared transfusion guided by TEG or ROTEM to transfusion guided by clinical judgement, guided by standard laboratory tests, or a combination. We also included interventional algorithms including both TEG and ROTEM in combination with standard laboratory tests or other devices. The primary analysis included trials on TEG or ROTEM versus any comparator. DATA COLLECTION AND ANALYSIS: Two review authors independently abstracted data; we resolved any disagreements by discussion. We presented pooled estimates of the intervention effects on dichotomous outcomes as risk ratios (RRs) with 95% confidence intervals (CIs). Due to skewed data, meta-analysis was not provided for continuous outcome data. Our primary outcome measure was all-cause mortality. We performed subgroup and sensitivity analyses to assess the effect of a TEG- or ROTEM-guided algorithm in adults and children on various clinical and physiological outcomes. We evaluated potential bias by examining trial methodological components using the Cochrane Risk of Bias 1 and assessed the risk of random error through Trial Sequential Analysis (TSA). MAIN
resultsThis systematic review included 35 randomised trials (n = 3096), with most involving patients undergoing elective cardiac surgery. Hence, 18 trials and 1603 participants were added since the previous update of this review. TEG-/ROTEM-guided transfusion algorithms may be associated with a reduction in mortality (RR 0.76, 95% CI 0.63 to 0.92; 19 trials; 1865 participants, I AUTHORS'
conclusionsTEG-/ROTEM-guided transfusion algorithms may reduce the risk of mortality, bleeding volume, and the need for fresh frozen plasma, platelets, and surgical re-intervention, but the evidence is very uncertain. Furthermore, the results were primarily based on the adult population undergoing elective cardiac surgery. Hence, the conclusion remains unchanged from the previous update of this review. There is a need for large, low risk of bias randomised controlled trials evaluating TEG/ROTEM across diverse clinical settings, including paediatric and neonatal populations, sepsis, trauma, obstetrics, and high-risk surgical and critically ill cohorts requiring major transfusion. Future studies should be adequately powered and prioritise patient-centred outcomes such as long-term survival, adverse events, cost-effectiveness, and the role of TEG/ROTEM in coagulopathy and severe haemorrhage.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.