Design of a next-generation conventional scintillator x-ray detector: Improved spatial resolution and fill factor.

Scott S Hsieh

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Scott S HsiehDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

Funding

Development of a quasi-ideal photon counting x-ray detector with spectral coincidence countersU01EB037558 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI Scott Sigao Hsieh, Hung Ngo · 2025 to 2026
$1.4M
Improving the dose efficiency of photon counting CTR01EB035553 · NIBIB · MAYO CLINIC ROCHESTER · PI Scott Sigao Hsieh · 2024 to 2026
$1.1M
NIBIB NIH HHS R01 EB035553NIH HHS R01EB035553NIH HHS U01EB037558
6 · The paper itself

Abstract

backgroundThe most compelling advantage that photon counting detectors (PCDs) currently have over energy integrating detectors (EIDs) for CT applications may be their improved spatial resolution. However, PCDs are difficult to manufacture. Next-generation EIDs using conventional scintillator sensors could be easier to mass produce, but their spatial resolution is thought to be limited by fill factor considerations. Specifically, each EID pixel comprises a block of scintillator surrounded by inactive, optically reflective septa. The minimum width of optically reflective septa is ∼0.1 mm, and unless this is shrunk, decreases in pixel pitch inevitably cause an increasing fraction of dead space. PURPOSE: To propose a modified system geometry in which the detector pixels are tilted by a few degrees, such that rays that are incident on reflective septa would later encounter scintillator. Because reflective septa are nearly transparent to x-rays compared to scintillator, this geometry restores much of the lost fill factor.

methodsTilting can be achieved in several different ways. We discuss three implementation options: individual detector modules may be tilted, with gaps between modules that are seamless from the perspective of the x-ray source; the whole detector can be arranged to point towards a "false" focal spot that is offset slightly from the true focal spot; the scintillator wafer can structured differently, e.g. by sawing it at an angle. The pros and cons of each option are discussed. Tilting introduces blurring, but a smaller pixel size improves resolution, and the combination of both improves both resolution and fill factor. We used Monte Carlo simulations to compare a conventional detector with 1.0 mm, 0.75, or 0.5 mm pixel pitch to a tilted detector with 0.5 mm pixel pitch. We assumed negligible optical crosstalk and electronic noise, that the scintillator was 1.5 mm thick with attenuation similar to gadolinium oxysulfide, that the reflective septa was 0.1 mm wide at standard resolution or 0.08 mm at higher resolutions and composed of a low-attenuating polymer similar to acrylic infused with 20% titanium content. We also compared this to a simple model of a CdTe detector with 1.6 mm thickness, 0.3 mm pixel pitch, and Gaussian charge sharing.

resultsTilt increases the aperture of the pixel in an energy-dependent fashion. With a 1D ASG (85% fill factor) and at 120 kVp, the detection efficiencies (DQE(0)) of a conventional detector at 1.0 mm, conventional detector at 0.5 mm pixel pitch, CdTe detector, and tilted detector at 0.5 mm pixel pitch are 65%, 55%, 66%, and 64%, respectively. With a sparse 2D ASG (1.5 × 3.0 mm openings, 86% fill factor), the DQE(0) of a tilted detector with 0.75 mm is 69%. The DQE(0) of all detectors decreases at higher energy because of punch-through.

conclusionsBy tilting detector modules a few degrees, energy-integrating detectors can provide increases in spatial resolution without the expected losses in fill factor. This architecture could bring the resolution improvements associated with photon counting CT into the domain of energy-integrating detectors equipped with conventional scintillator sensors.

Indexed as

Scintillation CountingTomography, X-Ray ComputedEquipment DesignPhotonsSignal-To-Noise RatioX-Raysdetector resolutionphoton countingscintillator detecto