Evidence map›Paper›PMID 42138490›Full record

ArticleLasers in surgery and medicine2026

Enhancing the Efficacy of Noncontact Laser Ablation of Weakly Absorbing Cholesteatoma Tissue Using a Blood Layer.

Paula Enzian, Kimberley Lühring, Birgit Lange, David Leffers, Karl-Ludwig Bruchhage, Anke Leichtle, Ralf Brinkmann

Abstract read
In one paragraph

Article in Lasers in surgery and medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Paula EnzianMedical Laser Center Lübeck, Lübeck, Schleswig-Holstein, Germany.ORCID https://orcid.org/0009-0007-4600-695X
Kimberley LühringMedical Laser Center Lübeck, Lübeck, Schleswig-Holstein, Germany.
Birgit LangeMedical Laser Center Lübeck, Lübeck, Schleswig-Holstein, Germany.
David LeffersDepartment of Otorhinolaryngology, Head and Neck Surgery, University Hospital Schleswig-Holstein, Lübeck, Schleswig-Holstein, Germany.
Karl-Ludwig BruchhageDepartment of Otorhinolaryngology, Head and Neck Surgery, University Hospital Schleswig-Holstein, Lübeck, Schleswig-Holstein, Germany.
Anke LeichtleDepartment of Otorhinolaryngology, Head and Neck Surgery, University Hospital Schleswig-Holstein, Lübeck, Schleswig-Holstein, Germany.
Ralf BrinkmannMedical Laser Center Lübeck, Lübeck, Schleswig-Holstein, Germany.

Funding

Federal Ministry of Research, Technology and Space 13N15846Federal Ministry of Research, Technology and Space 13N15847
6 · The paper itself

Abstract

objectivesThe 445 nm diode lasers have already been used successfully and safely for cholesteatoma surgery. However, the ablation of low absorbing and strongly scattering anemic tissue, such as keratinizing squamous epithelium of the cholesteatoma becomes challenging with low laser power. The initiation of ablation often occurs abruptly and not reproducibly with a noticeable acceleration after the start of carbonization. This study investigates whether a thin layer of blood on an adequate tissue model can improve light absorption and ablation. MATERIALS AND

methodsPorcine aortic tissue served as a model for pale, weakly absorbing tissue. Blood volumes of 2.5-110 μL were pipetted onto punch samples with a diameter of 12 mm. Tissue ablation was performed with a 445 nm diode laser at continuous wave powers of 1 W and 4 W at working distances of 1 mm and 2 mm to the distal tip of the transmitting multimode optical fiber, being moved with a speed of 5 mm/s across the tissue. Ablation depths and blood layer thicknesses were measured using optical coherence tomography (OCT). A theoretical model was used to estimate the optimal amount of blood to achieve the deepest ablation.

resultsDifferent blood layer thicknesses were examined, ranging from 17 μm to 1.3 mm. With the blood layer thickness of 50-100 μm the maximum ablation depth of approximately 370 μm was measured with a power of 4 W. Without blood, no ablation was achieved. However, it could be shown that the optimal blood layer thickness depended on the selected parameters, such as laser power and working distance. The experimental results closely matched model predictions, confirming the model's validity in estimating the ablation outcomes.

conclusionA thin blood layer enhances laser ablation of low-absorbing tissue with 445 nm laser radiation, such as cholesteatoma, allowing precise tissue removal.

Indexed as

CholesteatomaLasers, SemiconductorLaser TherapyAnimalsAortaSwineTomography, Optical Coherenceblood absorption layerblue lasercholesteatomalaser ablationotorhinolaryngology

Identifiers

PMID42138490
PMCPMC13466007

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.