Dynamic Manipulation Skill Learning for Tactile Myoelectric Prosthetic Hands in Tool Handling.

Boao Li, Shuhui Wu, Ting You, Shixian Wang, Ziming Chen, Ye Liu, Di Guo, Fuchun Sun, Guangyuan Xu, Du Jiang and 2 more

Abstract read
In one paragraph

Article in Cyborg and bionic systems (Washington, D.C.), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Boao LiKey Laboratory of Metallurgical Equipment and Control Technology of Ministry of Education, Wuhan University of Science and Technology, Wuhan 430081, China.ORCID https://orcid.org/0009-0003-2676-8579
Shuhui WuSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.
Ting YouBeijing Sport University, Beijing 100084, China.
Shixian WangSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.
Ziming ChenGuangdong Institute of Intelligence Science and Technology, Guangdong 519031, China.
Ye LiuSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.
Di GuoSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.
Fuchun SunInstitute for Artificial Intelligence, State Key Lab of Intelligent Technology and Systems, Tsinghua University, Beijing 100084, China.
Guangyuan XuSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.
Du JiangInstitute of Embodied AI, Wuhan University of Science and Technology, Wuhan 430081,China.
Gongfa LiInstitute of Embodied AI, Wuhan University of Science and Technology, Wuhan 430081,China.
Bin FangSchool of Artificial Intelligence, Beijing University of Posts and Telecommunications, Beijing 100080, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous tool operation with a myoelectric prosthetic hand is considerably more complex than discrete grasping tasks. This complexity arises because the control system must maintain stable, adaptive, and coordinated motions under varying loads and unpredictable interactions. In human motor control, this stability is achieved through a biological sensorimotor closed loop, where tactile feedback continuously modulates neural signals to adapt to environmental changes. Inspired by these mechanisms for reducing grasp instability caused by external shocks, this study designed a multimodal controller termed the tactile, kinesthetic, and electromyography (EMG) bionic gripping controller (TKE-BGC). It integrates tactile, kinematic, and EMG information. Initially, multimodal data-encompassing tactile signals, joint angles, and EMG patterns-were collected from able-bodied users during tool manipulation via a data glove. Subsequently, the TKE-BGC model was trained on these data, utilizing a Transformer encoder to extract high-level features and a multilayer perceptron to predict joint angles in real time. Based on this controller, this paper presents a prosthetic control framework developed through human skill transfer. Unlike conventional fixed force or force follows strategies that struggle with dynamic impacts or tracking delays, this framework enables robust end-to-end adaptive control. Tested across 4 seen and unseen tool operation tasks, the proposed method demonstrated precise detailed performance. Specifically, it significantly reduced the number of tool drops and shortened task completion times compared to the baseline methods. Furthermore, it achieved human-like average contact forces and substantially lowered the user's physical workload, requiring noticeably less muscle effort than the force follows strategy (e.g., average EMG amplitude, 0.0023 versus 0.0124). By rapidly adjusting grip force through feedback and effectively mitigating instability, this research holds significant practical value in enhancing the daily independence of amputees and supporting their vocational rehabilitation and reemployment.

Identifiers

PMID42137063
PMCPMC13168764

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked