Evidence map›Paper›PMID 42136119›Full record

ReviewJournal of clinical laboratory analysis2026

Performance Evaluation of Automated Urit 5160 Haematology Analyser at the Bamenda Regional Hospital, Cameroon.

Victor N Fondoh, Loveline L Niba, Mary B Atanga

Abstract readReview
In one paragraph

Review in Journal of clinical laboratory analysis, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Victor N FondohDepartment of Public Health, Faculty of Health Sciences, The University of Bamenda, Bambili, Cameroon.
Loveline L NibaDepartment of Public Health, Faculty of Health Sciences, The University of Bamenda, Bambili, Cameroon.
Mary B AtangaDepartment of Nursing and Midwifery, Faculty of Health Sciences, The University of Bamenda, Bambili, Cameroon.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Urit 5160 is a five-part leucocyte automated haematology analyser routinely used to improve workflow, patient management, and research. It is essential to confirm the instrument's performance by examining objective evidence that the laboratory can achieve the manufacturer-provided performance characteristics. Surprisingly, some analysers are used without evaluation. Our objectives were to evaluate the performance characteristics of Urit 5160 using blank count, precision, carryover, linearity, and method-comparison experiments to improve workflow, patient management, and research. MATERIAL AND

methodsThis was a cross-sectional prospective study conducted between October 2024 and March 2026 at the Bamenda Regional Hospital Laboratory, Cameroon. The parameters examined included: White Blood Cell Count, Haemoglobin, Red Blood Cell Count, Haematocrit, and Platelet Count. Excellent agreement was considered if the results from various experiments matched the manufacturer-provided specifications. Method comparison was performed by analysing 100 specimens in parallel on Urit 5160 and 3000 plus (reference instrument). Bland-Altman plots and Passing-Bablok regression analysis were used to evaluate the slopes, intercepts, and bias relative to the total allowable error (TEa) limits.

resultsOur results demonstrated acceptable blank count (0.0%), imprecision (%CV ≤ 3.9), carry-over (≤ 0.6%), and linearity (r ≥ 0.999) and the comparison study across all parameters. Bland-Altman analysis and Passing-Bablok regression showed acceptable correlation and minimal bias.

conclusionThe instrument demonstrated acceptable blank count, imprecision, carry-over, linearity, and method comparison within the constraints of the comparator instrument-Urit 3000 plus across all parameters. Thus, laboratories should ensure that manufacturer-provided characteristics are verified before instruments are routinely used.

Indexed as

Automation, LaboratoryHematologic TestsCameroonCross-Sectional StudiesHumansLeukocyte CountProspective StudiesReproducibility of Resultscarryoverevaluation performancelaboratory method verificationlinearitymethod comparisonprecisionUrit 5160