ArticleMagnetic resonance in medicine2026
SelExNet: A Self-Supervised Physics-Informed Framework for Multi-Channel Joint RF and Gradient Waveform Optimization in 2D Spatially Selective Excitation.
Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeTo introduce SelExNet: a self-supervised framework for two-dimensional spatially selective excitation that jointly optimizes radiofrequency (RF) pulses and gradient waveforms, and extends to multi-channel transmission MRI.
methodsBuilding on prior RF-only and joint RF-gradient optimization approaches, SelExNet couples neural RF and gradient generators with a differentiable Bloch simulator to enable self-supervised pulse optimization without requiring pre-designed target pulses. The framework jointly designs RF pulses and parameterized variable-density spiral gradient waveforms for both single- and multi-channel transmission, with patient-specific adaptation using measured, previously unseen
resultsJoint optimization of RF and gradients improved excitation fidelity compared to RF-only optimization. In phantom experiments with synthetic field maps, pretrained pulses showed distortions, whereas fine-tuned pulses restored geometry and uniformity. In vivo studies demonstrated anatomically precise excitation, with fine-tuning improving sharpness and reducing off-target signal.
conclusionThe proposed framework enables joint RF-gradient design and extends self-supervised pulse optimization to multi-channel transmission MRI. SelExNet achieves high-fidelity, anatomically precise excitation and demonstrates robustness to field inhomogeneities, offering a scalable pathway for ultra-high field imaging.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.